Skip to main content
ABB ACS880-01-014A-5+E200 — AC Drive (VFD) 480V

ABB ACS880-01-014A-5+E200 Inverter, 14 A, 7.5 kW

MPNACS880-01-014A-5+E200

ABB ACS880-01-014A-5+E200 wall-mounted inverter drive, 14 A output, 7.5 kW / 10 HP, 0–440/480 V 3-phase input, 0–500 Hz output, IP21, used condition.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ACS880-01-014A-5+E200 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)IP21
Mounting typeWall-mounted
ACS880-01-014A-5+E200 — Environmental
ParameterValue
Temperature rating (max.)Max. 40 °C

Product details

The drive on the bench

The ABB ACS880-01-014A-5+E200 is a wall-mounted inverter drive rated 14 A continuous output at 7.5 kW / 10 HP. The +E200 suffix sits on the standard ACS880-01-014A-5 base, which is the code a buyer arriving at this exact MPN needs to confirm matches the BOM line before signing the RFQ. Line-side it accepts a 3-phase supply across 0 – 440 / 480 V at 47 – 63 Hz. Motor-side it delivers up to 500 Hz output. Ambient ceiling is 40 °C with IP21 protection — a cabinet build, not an open floor-mount, and anything above 40 °C needs the thermal derate curve on the nameplate side.

On the control board you get 2 analog inputs, 2 analog outputs, 6 digital inputs and 2 digital outputs — enough headroom for a reference/feedback pair plus a couple of interlocks without bolting on an FIO module. Footprint is 9.8 x 6.1 x 16 inch at 7,82 kg — a wall-mount back-plate build, not a DIN-rail part.

Sizing sibling worth knowing

The adjacent ACS880-01 frame in the catalogue is the ACS880-01-017A-5 — the next current step up in the same wall-mount family. If the motor nameplate actually calls for 17 A continuous, this 14 A unit is the wrong frame and the MRO planner should spec the 017A instead, not oversize the 014A's parameter set.

Sourcing posture

For an active BOM line that needs the exact 014A-5+E200 configuration, the right move is to quote the RFQ against this code and confirm the option suffix +E200 maps to the same firmware/license set the rest of the cabinet was programmed for.

Frequently asked questions

What is the listed type on the Frequency Inverters line for this code?

The record classifies it as a Memory Card / inverter drive entry under Frequency Inverters, with the model field carrying ACS880-01-014A-5+E200.

What are the headline ratings a buyer needs to confirm fit?

14 A continuous output, 7.5 kW / 10 HP, 0–440/480 V 3-phase input, 0–500 Hz output, IP21, wall-mounted, rated to a 40 °C ambient.

Will it drop into a panel specified around the ACS880-MU-Z-AINL4?

The evidence on the MU-Z-AINL4 peer is just the same spec row echoed back, so a rewiring decision can't be grounded from this ledger. Treat the swap as not confirmed and validate against the fieldbus and option-suffix map before committing.

MPN
ACS880-01-014A-5+E200