Skip to main content
Mitsubishi Electric FR-E840-0170-4-60

Mitsubishi Electric FR-E840-0170-4-60 AC Drive, 400 V

MPN FR-E840-0170-4-60

Mitsubishi Electric FR-E800 series AC drive, FR-E840-0170-4-60, 400 V class, 17.0 A ND rated current, three-phase input, circuit board coating, 2.4 kg.

$819.00 – $1,333.50 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

FR-E840-0170-4-60 specifications
ParameterValue
Product typeInverter FR-E800
Weight2.4 Kg

Product details

400 V class, 17.0 A ND — the FR-E800 compact

The Mitsubishi Electric FR-E840-0170-4-60 is a 400 V class AC drive from the FR-E800 series, rated 17.0 A in normal-duty (ND) mode. That 17.0 A ND current is the continuous output the drive can deliver to a motor at rated conditions — the number you use for sizing the motor branch circuit, not the peak or short-time rating. Three-phase input is standard for this 400 V class frame. The drive ships with circuit board coating as standard, which matters if the panel environment sees condensation or mild airborne contaminants — the coating adds a barrier against tracking and corrosion on the control board.

The 17.0 A ND rating at 400 V class means this drive is sized for a motor load drawing around 17 A at full load — typical for a 7.5 kW (10 HP) four-pole motor at 400 V. The ND rating is the ceiling for continuous duty; if the application requires overload for starting or intermittent high-torque, the drive's electronic thermal protection handles that within the ND envelope. The rated frequency initial setting is 50 Hz, which is the default output frequency for the drive at power-up. If the motor is 60 Hz rated, the parameter must be changed during commissioning — the drive itself supports both, but the factory default is 50 Hz. Monitoring output is voltage at terminal AM, a standard analog output for speed or load indication. The safety stop signal is source logic (fixed) — that means the safety input expects a 24 V DC source signal to enable the drive, which is the common configuration for safety relays and PLC safety outputs in a 24 V control system.

Current production — sourcing posture

Sourced through independent distribution against an RFQ. No stock-holding claim on this page; the supply posture is quoted-to-order from authorized channels.

MPN
FR-E840-0170-4-60