Skip to main content
Mitsubishi Electric FX2N-20GM

Mitsubishi FX2N-20GM Positioning Module, EOL, 2-Axis Pulse O

MPN FX2N-20GM
End of Life

Mitsubishi FX2N-20GM positioning module, EOL, 2-axis pulse output, 200 kHz, CLR DC 5-24V, 7.8k step RAM.

$828.00 – $2,402.75 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

FX2N-20GM specifications
ParameterValue
Frequency57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
Temp operating max70 °C
Temp operating min-20 °C
Output methodOpen collector transistor output
Positioning range-999,999 to + 999,999 [X (minimum command unit) pulse] -999,999 to + 999,999 [X (minimum command unit) mm] -999,999 to + 999,999 [X (minimum command unit) X 10 -1 inch] -999,999 + 999,999 [X (minimum command unit) deg] The minimum command unit can be set to x 1, x 10 -1 , x 10 -2 or x 10 -3 in the parameter. However, at the time of Pulse unit, X 1, X 10 1 , X 10 2 , X 10 3
Pulse output methodOpen collector output

Product details

The Mitsubishi FX2N-20GM is a standalone 2-axis positioning module with open-collector pulse output at 200 kHz (100 kHz interpolation). It accepts DC 24 V ± 15% and runs as a smart peripheral or stand-alone controller.

Key ratings that decide fit

The CLR (clear) input range is DC 5 V to 24 V — common for 24 V PLC I/O or 5 V TTL-level encoders. The DOG (near-point dog) signal requires a pulse width of about 0.5 ms; the zero-point signal (PG 0) typical response is about 16 µs. These timing specs matter when replacing a failed module: if your machine relies on a faster or slower dog sensor, the position capture may shift.

Integration notes

Mounts on a DIN rail in the FX2N bus extension. Requires a dedicated Class D ground (100 Ω or less). Supply current is 10 W from the 24 V external supply; a 125 V, 1 A fuse protects the module. Input signals accept contact or NPN open-collector, 24 V nominal. The module cannot be used above 2000 m altitude without derating, and must not be installed in environments with corrosive gas, flammable gas, or excessive conductive dust.

MPN
FX2N-20GM