Skip to main content
Omron E5CC-QX2ABM-001

Omron E5CC-QX2ABM-001 Temperature Controller, PID

MPN E5CC-QX2ABM-001
Active

Omron E5CC series process/temperature controller, PID control, universal input, relay + voltage (SSR drive) outputs, 100–240 VAC supply, spring terminal, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5CC-QX2ABM-001 specifications
ParameterValue
SeriesE5CC
Output signalRelay (2), Voltage (External SSR)
Supply voltage100 to 240VAC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

Universal input, dual-output controller for panel-mount loops

The Omron E5CC-QX2ABM-001 is a panel-mount process and temperature controller that accepts RTD, thermocouple (Types B, E, J, K, L, N, PLII, R, S, T, U, W), 0–20 mA, or 0–10 VDC input — so one part number covers most loop types on a machine without swapping modules. It runs on 100–240 VAC, meaning no separate 24 VDC power supply needed in a standard control panel. The front face carries an IP66 rating, so it stands up to washdown splashes and dust on the panel door. Outputs are two relay contacts plus a voltage pulse for an external SSR — enough to drive a contactor for heater power and a solid-state relay for proportional control without adding a second controller. The control method is On/Off or PID, selectable per loop, with autotune to set PID gains on commissioning.

Spring terminals and event inputs cut wiring time

Termination is spring-clamp, not screw — push a ferrule into the cage and it holds. That shaves a few minutes per panel when you're wiring a dozen of these. The panel cutout is a standard 45.00 mm square, so it drops into existing DIN-style punch-outs or a dedicated bezel. Built-in event input lets you switch between two setpoints or start/stop control from a PLC dry contact without extra terminals. Heater fault detection monitors current draw on the load side and flags a broken heater element — useful on a molding press or oven where an undetected open heater drifts the process. Display is a dual-color LCD with two rows of characters — the top row shows the process value in 0.600" digits, the bottom shows setpoint in 0.280" digits. That's readable from a few steps back on the factory floor.

Active production, sourced to order

If the controller sits near a hot oven or in a non-conditioned cabinet, stay inside that envelope — the electronics and LCD are the limit.