Skip to main content
Omron E5EC-RX2ABM-011

Omron E5EC-RX2ABM-011 Temperature Controller

MPN E5EC-RX2ABM-011
Active

Omron E5EC-RX2ABM-011 temperature controller, 4 relay outputs, 100-240VAC supply, spring terminal, IP66 front panel, 92x45mm cutout.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-RX2ABM-011 specifications
ParameterValue
SeriesE5EC
Output signalRelay (4)
Supply voltage100 to 240VAC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

What it is and what it controls

The Omron E5EC-RX2ABM-011 is a 1/8 DIN temperature controller accepting RTD and thermocouple inputs (Types B, E, J, K, L, N, PLII, R, S, T, U, W) plus 0-20mA or 0-10VDC linear signals. It provides four relay outputs for control and alarm functions, with On/Off or PID control methods selectable per application. The input range spans -200°C to 2300°C depending on sensor type, covering most industrial heating processes from cryogenic to high-temperature furnaces.

Panel fit and wiring

Panel mount with a 92.00mm x 45.00mm rectangular cutout — standard 1/8 DIN footprint that drops into existing panel holes without modification. Spring terminal connections eliminate screw tightening; solid or ferruled stranded wire pushes in directly, saving time on the panel assembly line. IP66 front-panel rating means the display and keypad withstand washdown and dust ingress — suitable for food, beverage, or outdoor enclosures where the controller face is exposed.

Heater fault detection and display

Built-in heater fault detection monitors the load current via an external CT and triggers an alarm if the heater circuit opens or degrades — catches a failed SSR or broken element before the process drifts. The tri-color LCD backlight changes color (green, orange, red) to indicate process status at a glance — set it to red on alarm so operators see the fault from across the line. Three display rows show PV, SV, and a third parameter simultaneously, each with 4 characters; character heights of 18.00mm, 11.00mm, and 7.80mm make the primary process value readable from several meters.

Sourcing and lifecycle

Sourced through authorized distribution channels; quoted to order against the BOM quantity with lead time and volume pricing confirmed at RFQ.

MPN
E5EC-RX2ABM-011