Omron E5EC-RX4DBM-011

Omron E5EC-RX4DBM-011 Temperature Controller, 24VAC/DC

MPN E5EC-RX4DBM-011
Active

Omron E5EC-RX4DBM-011 temperature controller, E5EC series, relay output, 24VAC/DC supply, IP66 front panel, spring terminal, panel mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-RX4DBM-011 specifications
ParameterValue
SeriesE5EC
Output signalRelay (5)
Supply voltage24 VAC/DC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

What this controller handles

The E5EC-RX4DBM-011 is a 1/8 DIN temperature controller accepting RTD and thermocouple inputs (B, E, J, K, L, N, PLII, R, S, T, U, W) plus 0–20 mA or 0–10 VDC linear signals. That input range covers -200°C to 2300°C, so it spans cryogenic to high-temp furnace work without a separate signal conditioner. Five relay outputs handle the control loop and alarms. The control method is On/Off or proportional (PID), which is the standard choice for thermal processes where overshoot matters — plastic injection mold zones, packaging seal bars, or oven zones.

Panel fit and environmental sealing

Panel cutout is 92.00 mm x 45.00 mm — the standard 1/8 DIN footprint. The IP66 front-panel rating means the controller face withstands washdown spray and dust ingress, so it lives on the front of a food-grade or washdown enclosure without a secondary cover. Spring terminals on the back speed wiring — no screw torque to check, just strip and push. Supply voltage is 24 VAC/DC, which is common in control panels that already run 24 V for sensors and PLC I/O.

Heater fault detection and display

Built-in heater fault detection monitors the load current through an external CT and flags a broken heater element or SSR short. That's a real time-saver on a multi-zone machine — the controller tells you which zone dropped out instead of waiting for a temperature deviation alarm. The tri-color LCD backlight shows three rows of four characters each, with the largest digits at 0.710" (18.00 mm) for the process value. The operator sees the PV, SV, and status at a glance from across the panel.

Lifecycle and sourcing

Sourced to order against the BOM quantity through independent distribution.

MPN