Skip to main content
Omron MY2K-US-DC48

Omron MY2K-US-DC48 Latching Relay, DPDT, 48 VDC

MPN MY2K-US-DC48

Omron MY2K-US-DC48 magnetic-latching relay, DPDT (2-pole), plug-in terminal, 48 VDC coil, 3 A max switching, RoHS compliant.

$39.65 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

MY2K-US-DC48 specifications
ParameterValue
Coil voltage48 VDC
Temp operating max60 °C
Temp operating min-55 °C

Product details

What a magnetic-latching DPDT plug-in relay actually does

The Omron MY2K-US-DC48 is a magnetic-latching relay in the MYK family, defined as a DPDT (2-pole) plug-in device whose contacts hold their last position after the coil is de-energized — ideal for memory- and data-transmission circuits where the output state must survive a power interruption. The set and reset coils run at 48 VDC with a set power of approximately 1.3 W and a reset power of approximately 0.6 W. Two separate coil inputs on the same relay let a logic pulse flip the contacts in either direction without continuous coil hold current, which is the defining advantage of the latching form factor over a standard non-latching DPDT relay.

Contact ratings and what they mean for the load

Maximum switching current is 3 A with a maximum switching voltage of 250 VAC or 125 VDC. The headline 3 A figure is the resistive ceiling; on inductive loads the ratings drop to 0.8 A at 220 VAC and 1.5 A at 24 VDC, while on resistive loads they hold at 3 A at both 220 VAC and 24 VDC. Switching power tracks the same split: 176 VA / 36 W on inductive loads versus 660 VA / 72 W on resistive loads. For a buyer matching this relay to a real load, the duty category — not the headline 3 A — is the figure that governs fit: a relay driving a solenoid or small contactor coil must be sized against the 0.8 A inductive rating, not the 3 A resistive figure.

Low-level switching and panel-side integration

The minimum load of 1 mA at 1 VDC means the contacts are rated for dry-circuit and low-level signal switching, so the relay can sit at the boundary between logic-level telemetry and a higher-current output without a separate interposing relay. Operating temperature runs from -55 °C to 60 °C, covering both unheated outdoor cabinets and standard panel interiors. The plug-in terminal style fits the standard MY-series octal/ blade socket pattern used across the Omron MY family, so panel wiring is a matter of matching the correct socket and pinning the two coil inputs plus the DPDT commons to the wiring layout. RoHS compliance is confirmed on the device record.

Sourcing posture for MY2K-US-DC48

The lifecycle stage is recorded as mature. No stock or lead-time figures are published on this page.

MPN
MY2K-US-DC48