Siemens 3RH2911-2GA40 SIRIUS Auxiliary Switch, 4 NO, 10 A

MPN 3RH2911-2GA40
Active

Siemens SIRIUS auxiliary switch, 3RH2911-2GA40, 4 NO contacts, 10 A maximum, spring-loaded terminals, snap-on mounting, IP20 front.

$6.27 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RH2911-2GA40 specifications
ParameterValue
MountingSnap-on Mounting
Depth47.7 mm
Width36 mm
Height41.5 mm

Product details

The Siemens SIRIUS 3RH2911-2GA40 is a front-mounted auxiliary switch block delivering 4 normally-open (NO) contacts, labelled 53/54, 63/64, 73/74, and 83/84 per EN 50011. It's designed specifically for use with 3RH2140 and 3RH2440 contactor relays — physically coded so it only fits those frames. Rated at 10 A maximum, with a 10 A continuous rating at 24 V. The AC-15 switching capacity at 690 V is 1 A — that's the figure that governs solenoid and contactor coil loads in a control panel. Spring-loaded terminals accept 2x (0.5 to 1.5 mm²) with ferrules, or 2x (0.5 to 2.5 mm²) solid, which covers most panel wiring without needing bootlace ferrules. Snap-on mounting onto the contactor relay — no tools needed for the install, but verify the physical coding matches the relay frame before you push it on.

Switching capacity across voltages

The 3RH2911-2GA40's contact ratings vary significantly with voltage and load type. For DC switching: 6 A at 24 V, 6 A at 125 V, 6 A at 230 V, 6 A at 250 V, but drops to 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, and 3 A at 400 V. For AC-15 inductive loads at 690 V, it's rated 1 A. The 6 kV surge voltage resistance gives it decent margin for transient suppression on the coil side.

The 3RH2911-2GA40 carries a current lifecycle stage per the manufacturer's classification. It's a standard catalog item in the SIRIUS auxiliary switch range, not flagged for phase-out.

Mechanical endurance and contact reliability

Rated for 10 million mechanical switching cycles typical.

Panel integration

Dimensions: 36 mm wide, 41.5 mm high, 47.7 mm deep. Snap-on mounting onto the contactor relay frame — no DIN rail required, it clips directly to the 3RH2140 or 3RH2440. The spring-loaded terminals are physically coded to prevent mis-mating.

MPN
3RH2911-2GA40