Skip to main content
Siemens 3RT1056-6PP35-0SW0

Siemens 3RT1056-6PP35-0SW0 SIRIUS Power Contactor, S6

MPN 3RT1056-6PP35-0SW0

Siemens SIRIUS 3RT1056-6PP35-0SW0 power contactor, size S6, 132 kW at 500 V AC-3, screw fixing, screw-type coil terminals, 172 x 170 x 140 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RT1056-6PP35-0SW0 specifications
ParameterValue
Mountingscrew fixing
Depth170 mm
Width140 mm
Height172 mm
Arcing time10 ... 15 ms

Product details

S6 frame, 132 kW at 500 V — the panel fit and the load it carries

The 3RT1056-6PP35-0SW0: This is a Siemens SIRIUS power contactor in the S6 frame size, rated for motor switching at 132 kW at 500 V in AC-3 duty — the standard category for squirrel-cage motor starting under load. The 172 mm height, 170 mm depth, and 140 mm width define the panel footprint; screw fixing through 9 mm diameter holes secures it to the backplate. The coil operates on 200–277 V AC at 50/60 Hz with a pick-up threshold of 0.8 × rated voltage and a drop-out ceiling of 1.1 × rated voltage. Coil connections are screw-type terminals, matching the main power circuit termination style.

Duty-cycle limits and switching capacity across the voltage range

Maximum operating rates vary by duty: 800 cycles/hour in AC-1 (resistive), 750 cycles/hour in AC-3 and AC-3e (motor starting), 300 cycles/hour in AC-2 (slip-ring motor), and 130 cycles/hour in AC-4 (plugging/inching). The mechanical endurance is 10 million cycles typical, so the limiting factor in a high-duty application is the electrical life under the specific load current. Switching capacity is specified across multiple voltages: 10 A at 24 V, 6 A at 230 V, 3 A at 400 V, and 2 A at 60 V — these figures govern auxiliary contact or control-circuit switching, not the main motor path. The main poles carry the 132 kW motor rating at 500 V.

Clearance, conductor sizing, and environmental limits

Minimum clearances to adjacent metalwork: 10 mm upwards, downwards, and to the side; 20 mm forwards. These distances matter when packing multiple contactors in a row — the arc-chamber venting needs that gap to avoid flashover between units. The main circuit terminals accept solid or stranded conductors: two conductors per clamp in the ranges 0.5–1.5 mm², 0.75–2.5 mm², and up to 4 mm² for the larger pair. Operating temperature range is -25 to +60 °C; storage range is -55 to +80 °C. Coil pick-up time is 80–90 ms for both AC and DC control supplies; arcing time is 10–15 ms. These timing figures matter for coordination with upstream short-circuit protection devices and for sequencing multiple contactors in a motor control centre.

MPN
3RT1056-6PP35-0SW0