Skip to main content
Siemens 3RV2131-4RA10

Siemens 3RV2131-4RA10 SIRIUS Motor Protection Circuit Breake

MPN 3RV2131-4RA10
Active

Siemens SIRIUS, motor protection circuit breaker with overload relay function, 3RV2131-4RA10, Trip Class 10, 30 kA breaking capacity at 400 V, screw terminals, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV2131-4RA10 specifications
ParameterValue
Depth149 mm
Width75 mm
Height140 mm
Trip classCLASS 10

Product details

Motor protection circuit breaker with integrated overload relay

The Siemens SIRIUS 3RV2131-4RA10 is a motor protection circuit breaker that combines short-circuit protection with an integrated overload relay function — one device, one footprint, no separate overload block to size and wire. Per the datasheet, it is designed specifically for motor protection with overload relay function, meaning it handles both the magnetic trip for fault currents and the thermal Class 10 overload curve for running protection. Breaking capacity is the headline number here: 30 kA at 400 V AC. That is the fault current it can safely interrupt without welding contacts or rupturing the housing. For a 400 V distribution panel with a transformer rating that keeps prospective fault current under 30 kA, this breaker coordinates without needing an upstream current-limiting fuse. At 690 V the rating drops to 2 kA, so verify the available fault current at the point of installation if running on a 690 V system. Phase failure detection is built in — if one phase drops out, the overload mechanism accelerates the trip, preventing single-phasing damage to the motor. No ground fault detection on this variant, so a separate ground-fault relay or RCD is needed if that is a code requirement.

Mounting and terminal details

Mounting is screw-fixed or snap-on onto 35 mm DIN rail per DIN EN 60715. The mounting position is any orientation, which simplifies panel layout. Clearance requirements: 50 mm upwards and downwards, 10 mm at the sides, zero forwards and backwards — so it can sit flush against a backplate or enclosure wall without derating. Main circuit terminals are M6 screw-type, accepting 2 x (1 to 35 mm²) or 1 x (1 to 50 mm²) solid or stranded copper. That covers most motor feeds up to the rated current range. The 75 mm width and 140 mm height mean it occupies roughly the same DIN footprint as a standard contactor of similar rating — plan for a 75 mm wide slot per device.

MPN
3RV2131-4RA10