Siemens 3RW4024-1TB04

Siemens 3RW4024-1TB04 SIRIUS Soft Starter, 12.5 A, 24 V, S0

MPN 3RW4024-1TB04
Active

Siemens SIRIUS soft starter, 3RW4024-1TB04, 12.5 A at 40 °C, 24 V control, S0 frame, screw terminals, integrated bypass.

$380.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4024-1TB04 specifications
ParameterValue
Mountingscrew and snap-on mounting
Depth155 mm
Width45 mm
Height125 mm

Product details

SIRIUS 3RW4024-1TB04 soft starter — 12.5 A, S0 frame, integrated bypass

The Siemens 3RW4024-1TB04 is a SIRIUS soft starter in the S0 frame size, rated 12.5 A at 40 °C and 24 V control voltage (50/60 Hz). It includes an integrated bypass contact system, so once the motor is up to speed the thyristors are shorted — no heat sink derating during run, and the bypass carries the full load current. That makes it a good fit for conveyors, pumps, and fans where you want a compact starter that doesn't waste panel space on an external bypass contactor.

At 40 °C the unit delivers 12.5 A continuous. Minimum load is 20% of the rated current — below that the soft starter may not fire the thyristors reliably, so don't use it on a motor that draws less than about 2.5 A at 40 °C.

Mounts via screw or snap-on to DIN rail. The S0 frame is 45 mm wide, 125 mm tall, 155 mm deep. Keep 60 mm free above and 40 mm below for airflow; side clearance is 15 mm. Without an external fan, the mounting surface must be within ±10° of vertical; with the optional fan you can rotate ±90° and tilt ±22.5° front/back. Storage temp range is -40 to +80 °C; operating ambient is -25 to +60 °C.

Main power circuit uses screw-type terminals; auxiliary and control circuit also screw-type. Solid wire accepted: 2x (0.5... 2.5 mm²). Auxiliary contacts: 2x (20... 14 AWG). Front clamping point: 1x 8 mm² or 2x (16... 10 AWG). Maximum wire length from the starter to the motor is 300 m — beyond that, voltage drop and capacitance may cause nuisance tripping.

Protection and control features

Built-in motor overload protection and intrinsic device protection are standard. Adjustable current limitation lets you set the starting torque profile. External reset input is provided. Insulation voltage rated 600 V. A red LED indicates fault status.

MPN
3RW4024-1TB04