Siemens 3RW4466-6BC45

Siemens 3RW4466-6BC45 SIRIUS Soft Starter, 2103 A at 40 °C

MPN 3RW4466-6BC45

Siemens SIRIUS 3RW4466-6BC45 soft starter, 2103 A at 40 °C, 690 V insulation voltage, integrated bypass contactor, inside-delta circuit capable, screw fixing mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW4466-6BC45 specifications
ParameterValue
Mountingscrew fixing
Depth292 mm
Width575 mm
Height780 mm

Product details

Current rating and thermal derating — what the numbers mean for your motor

The 3RW4466-6BC45 is rated 2103 A at 40 °C ambient. That current drops to 1864 A at 50 °C and 1680 A at 60 °C. If your panel ambient runs above 40 °C, the motor full-load current must stay under the derated figure — the thyristor junction temperature is the limit, not the nameplate. The operating frequency is 50/60 Hz, so it works on either line frequency without derating.

Panel fit — dimensions, cable terminations, and mounting

The unit measures 780 mm high by 575 mm wide by 292 mm deep. That is a substantial footprint — plan the gland plate and busbar routing before the panel layout is frozen. Mounting is screw fixing, not DIN rail; the mounting position allows vertical surface with +/-90° rotation and +/-22.5° tilt forward/back. Main circuit cable termination accepts stranded 70–240 mm² and finely stranded 50–240 mm², plus AWG 2/0–500 kcmil. The main current circuit uses busbar connection; auxiliary and control circuits use screw-type terminals.

Integrated protection and bypass — what is built in and what you still need

Motor overload protection, intrinsic device protection, and adjustable current limitation are all onboard. The integrated bypass contactor means the thyristors are shorted out after start — no continuous heat sink loss, which is why the enclosure can be smaller than a full SCR stack. Minimum load is 8 %, so it handles lightly loaded motors without dropping out. The inside-delta circuit capability allows the soft starter to be wired in the motor delta loop, reducing the current through each thyristor leg to 58 % of line current — useful for retrofitting into existing delta-wound motors without re-cabling the main power path.