Siemens 3RW5077-2AB05

Siemens 3RW5077-2AB05 Soft Starter, 240 A, ATEX, PROFINET

MPN 3RW5077-2AB05
Active

Siemens SIRIUS 3RW5077-2AB05 soft starter, 240 A minimum rated current, 200-600 V, ATEX and IECEx certified, PROFINET standard communication, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5077-2AB05 specifications
ParameterValue
Mountingscrew fixing
Depth282 mm
Width160 mm
Height230 mm
Trip classCLASS 10 A / 10E (preset) / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

The Siemens 3RW5077-2AB05 is a SIRIUS-series soft starter rated for a minimum set current of 240 A across a 200 to 600 V supply range, making it a fit for medium-horsepower induction motors — think pumps, fans, compressors, and conveyors in the 100–150 kW ballpark on 400 V three-phase. ATEX and IECEx certified per IEC 60947-4-2. Screw fixing; 160 mm wide, 230 mm high, 282 mm deep.

The 240 A minimum rating is the smallest motor current the starter can be set to — it is not a maximum. The actual maximum motor FLA it can handle depends on the overload relay selected and the ambient derating curve. Trip Class 10A / 10E (preset) / 20E per IEC 60947-4-2 means the starter can be configured for normal (Class 10) or extended (Class 20) acceleration profiles. Class 10A protects standard squirrel-cage motors during start; Class 20E allows longer ramp times for high-inertia loads like centrifuges. The analog output defaults to 4-20 mA and can be parameterized to 0-10 V via the High Feature HMI — useful for feeding motor current to a PLC or SCADA without an external transducer.

Communication and control options

This soft starter supports PROFINET standard, PROFIBUS, EtherNet/IP, Modbus RTU, and Modbus TCP natively — no separate communication module required for these protocols. It also supports PROFIenergy in conjunction with the PROFINET standard communication module, allowing energy-saving shutdown of the motor during idle periods in automated production lines. Remote reset is achieved by cycling the 24 V DC control supply voltage — no separate reset signal needed.

MPN
3RW5077-2AB05