Skip to main content
Siemens 3RW5225-1TC04

Siemens 3RW5225-1TC04 Soft Starter, 25.5 A min, 200-480 V

MPN 3RW5225-1TC04
Active

Siemens SIRIUS 3RW5225-1TC04 soft starter, 25.5 A minimum operating current, 200–480 V rated voltage, trip class 10A/10E/20E, PROFIBUS/Modbus/EtherNet/IP/PROFINET, UL/CSA/CE.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5225-1TC04 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

25.5 A minimum — sets the floor for motor sizing

The 3RW5225-1TC04: This SIRIUS soft starter has a minimum operating current of 25.5 A, meaning the connected motor's full-load current must be at or above that value for the unit to regulate startup torque properly. Below that floor, the current sensing loses accuracy and the trip class timing may not hold. Rated voltage covers 200 to 480 V, so it fits standard low-voltage three-phase supplies across North America (208/240/480 V) and Europe (230/400 V) without a separate transformer tap.

Trip class 10A — 10 seconds to manage heat buildup

Trip class is set to CLASS 10A by default, with selectable 10E and 20E options per IEC 60947-4-2.

Fieldbus onboard — PROFIBUS, Modbus, EtherNet/IP, PROFINET

The unit ships with PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET communication. No separate gateway module is needed for these four protocols — the soft starter talks directly to the PLC or SCADA. PROFIenergy is supported via the PROFINET standard module, allowing energy management data collection during idle phases.

Pump-specific features — Soft Torque and Pump Ramp Down

Soft Torque reduces the starting torque below the motor's locked-rotor torque, which helps on conveyors or pumps where a hard start can damage the belt or cause water hammer. Pump Ramp Down controls deceleration to prevent pressure surges when stopping a centrifugal pump — the unit ramps voltage down gradually rather than cutting power instantly. Auto-reset and remote reset by cycling the control supply are standard, so the starter can re-close after a fault without a manual pushbutton visit — useful for remote or unmanned stations.

MPN
3RW5225-1TC04