Skip to main content
Siemens 3RW5226-1AC15

Siemens 3RW5226-1AC15 Soft Starter, 32 A, 200-600 V, SIRIUS

MPN 3RW5226-1AC15
Active

Siemens SIRIUS 3RW5226-1AC15 soft starter, 32 A minimum, 200-600 V, CLASS 10A/10E/20E, screw fixing, 306x185x203 mm, PROFIBUS/Modbus/EtherNet/IP.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5226-1AC15 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

What 32 A minimum and CLASS 10A mean for motor starting

The 3RW5226-1AC15: The 32 A minimum setting on this SIRIUS soft starter sets the floor for motor full-load current — it won't reliably start a motor drawing less than 32 A, so match it to a motor nameplate above that threshold. Default trip class is CLASS 10A per IEC 60947-4-2, meaning the starter lets the motor draw starting current for up to 10 seconds before tripping — suitable for standard-load starts like pumps and fans. CLASS 10E and 20E are selectable for heavier inertia loads.

Fieldbus and communications — what's on board

Built-in PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET standard — no separate gateway module needed for common plant networks. PROFIenergy support is available when paired with the PROFINET standard communication module.

Mounting and clearance — panel fit

Screw-fixing mount with a 306 mm height, 185 mm width, and 203 mm depth. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm at the sides — plan the enclosure layout around these to avoid thermal recirculation.

Operating temperature and derating

Rated for -25 to +60 °C during operation, but derating applies above 40 °C — check the derating curve in the product documentation before sizing for a hot enclosure.

MPN