Siemens 3RW5234-6TC04

Siemens 3RW5234-6TC04 SIRIUS Soft Starter, 53 A, 200-480 V

MPN 3RW5234-6TC04
Active

Siemens SIRIUS 3RW5234-6TC04 soft starter, 53 A minimum, 200-480 V, Class 10A/10E/20E, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 306 x 185 x 203 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5234-6TC04 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1
Digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

What the 53 A minimum and trip class mean for your motor

The 3RW5234-6TC04: The 53 A minimum setting on this SIRIUS soft starter means it's sized for motor FLCs at or above that threshold — anything smaller and the current resolution won't give you a clean start profile. Trip class defaults to CLASS 10A per IEC 60947-4-2, which limits the start time to 10 seconds at locked-rotor current — a standard fit for centrifugal pumps and fans that don't need extended ramp times. You can switch to 10E or 20E if the load inertia demands a longer acceleration window. The 200-480 V rated supply covers common global motor voltages — 208 V, 230 V, 400 V, 460 V — without needing a tap change or separate transformer.

Fieldbus and control integration

This unit ships with onboard PROFIBUS, Modbus RTU, Modbus TCP, EtherNet/IP, and PROFINET — you can drop it into a Siemens S7-1500 or Rockwell ControlLogix rack without an extra gateway module. PROFIenergy support lets the soft starter coordinate with the controller during energy-saving idle phases — useful on conveyor lines where the motor can be stopped between batches. The 24 V DC control supply is standard for industrial panels — no need to run a separate AC control transformer for the logic.

Mounting and clearance — what fits in the panel

Screw-fixing to the backplate — 306 mm tall, 185 mm wide, 203 mm deep — so it needs a solid mounting surface, not a DIN rail. Clearance requirements: 100 mm above, 75 mm below, 10 mm forward, 5 mm sideways — plan the gland plate and busbar routing to stay inside those boundaries for airflow and arc flash. Mounting position is flexible — vertical surface with ±90° rotation and ±22.5° tilt front-to-back — so you can angle it in a tight cabinet as long as the vent paths aren't blocked.

UL and CSA approvals are confirmed — the unit carries CE marking as well, so it's accepted in North American and European installations without additional certification paperwork.

MPN
3RW5234-6TC04