Siemens 3RW5245-2AC04

Siemens 3RW5245-2AC04 SIRIUS Soft Starter, 135 A min

MPN 3RW5245-2AC04
Active

Siemens SIRIUS 3RW5245-2AC04 hybrid soft starter, 135 A min, 200-480 V, Class 10A/10E/20E, 24 V DC control, 393 x 210 x 203 mm, screw fixing.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5245-2AC04 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width210 mm
Height393 mm
Trip classCLASS 10 A (default) / 10E / 20E; acc. to IEC 60947-4-2
Service factor1

Product details

135 A minimum, 200-480 V — what that means for your motor start

The Siemens 3RW5245-2AC04 is a SIRIUS hybrid soft starter sized for a minimum motor current of 135 A on a 200 to 480 V supply. That 135 A floor is the smallest settable Ie — you cannot dial it lower, so it fits motors that draw at least that much full-load current. The 200-480 V range covers common three-phase industrial voltages (208, 240, 400, 480 V) without an internal tap change. Trip class defaults to Class 10A per IEC 60947-4-2, meaning it clears a stalled rotor in under 10 seconds at 7.2x Ie — fast enough to protect standard squirrel-cage motors. You can also select Class 10E or 20E via parameterization if the load has higher inertia (centrifuges, fans) that needs a longer ramp. Control supply is 24 V DC, which is the standard for modern PLC cabinets. The unit supports remote reset by cycling that control voltage — no need to walk to the panel to clear a trip.

Fieldbus fit: Modbus TCP, EtherNet/IP, PROFIBUS, PROFINET

This variant carries onboard Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS, plus PROFINET with PROFIenergy for coordinated energy management during idle periods. If your site runs a single protocol — say, EtherNet/IP on a Rockwell line — you don't need an extra gateway card. The analog output (4-20 mA default, or 0-10 V with the High Feature HMI) gives a direct speed/fault signal back to the PLC without bus polling.

Mounting and environment — screw-fixed, vertical, derate above 40 °C

Fastening is screw fixing — no DIN-rail clip on this size. Clearances: 100 mm above, 75 mm below, 10 mm front, 5 mm side, 0 mm back. The 393 x 210 x 203 mm envelope (H x W x D) is a substantial panel footprint — plan the backplate layout before drilling. In a warm enclosure near a motor drive or transformer, that derating matters — you may need to reduce the starting duty cycle or add ventilation. Shock resistance is 15 g / 11 ms, with potential contact lifting above 12 g. On a vibrating pump skid or near a large reciprocating compressor, bolt it down securely and consider isolation mounts if you measure sustained vibration above that threshold.

MPN
3RW5245-2AC04