Skip to main content
Siemens 3RW5534-6HA16

Siemens 3RW5534-6HA16 SIRIUS Soft Starter, 113A, ATEX

MPN 3RW5534-6HA16
Active

Siemens SIRIUS 3RW5534-6HA16 soft starter, 113 A rated operational current, ATEX/IECEx certified, 200-690 V, screw terminals, multi-protocol fieldbus.

$2,030.73 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RW5534-6HA16 specifications
ParameterValue
Mountingscrew fixing
Depth203 mm
Width185 mm
Height306 mm
Trip classCLASS 10 A / 10E (default) / 20E / 30E; acc. to IEC 60947-4-2
Service factor1.15
Digital output version3 normally-open contacts (NO) / 1 changeover contact (CO)

Product details

Soft starter for motor control in hazardous zones

The Siemens 3RW5534-6HA16 is a SIRIUS soft starter rated for 113 A operational current on 200-690 V supplies, carrying ATEX and IECEx certification for use in explosive atmospheres. Trip class is selectable between CLASS 10A, 10E (default), 20E, or 30E per IEC 60947-4-2. Screw terminals simplify field wiring, and the unit supports DC braking, voltage ramp, pump ramp down, torque control, and a breakaway pulse — covering the common starting modes for pumps, fans, conveyors, and compressors.

Fieldbus and monitoring suite

Built-in Modbus RTU, Modbus TCP, EtherNet/IP, and PROFIBUS mean this soft starter talks directly to most PLC environments without an external gateway. PROFINET with PROFIenergy is available via a communication module. The analog output (4-20 mA default or 0-10 V) can feed a motor current signal to a remote SCADA or local panel meter. On-board diagnostics include an event list, error logbook, trace function, and motor heating model. Accuracy class 5 per IEC 61557-12 means the current measurement is within 5 % — sufficient for overload monitoring and energy tracking without a separate CT. Firmware updates are supported, and four parameter sets can be stored for quick recipe changeovers.

Panel layout and clearances

Dimensions are 306 mm height, 185 mm width, 203 mm depth. Minimum clearance requirements: 100 mm above, 75 mm below, 10 mm in front, 5 mm at the sides, and 0 mm behind — the back can sit flush against the panel backplate. This allows dense packing in a standard 600 mm deep enclosure while maintaining airflow for heat dissipation.

MPN
3RW5534-6HA16