Skip to main content
Siemens 3SK1112-2BB40

Siemens 3SK1112-2BB40 SIRIUS Safety Relay, SIL 3 / PL e, 24

MPN 3SK1112-2BB40
Active

Siemens SIRIUS safety relay, 3SK1112-2BB40, 24 VDC, SIL 3 / PL e, solid-state enabling circuits, 2 instantaneous contacts, spring-loaded terminals, 22.5 x 100 x 91.6 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3SK1112-2BB40 specifications
ParameterValue
Mountingscrew and snap-on mounting
Depth91.6 mm
Width22.5 mm
Height100 mm

Product details

Safety relay for guarding applications — SIL 3 / PL e with solid-state enabling circuits

The Siemens 3SK1112-2BB40 is a SIRIUS safety relay designed for safety-related circuits in industrial guarding and hazard-zone applications. It achieves SIL 3 per IEC 61508 and PL e per ISO 13849-1, with a safe failure fraction (SFF) of 99 % — meaning it can detect and signal a dangerous fault with very high diagnostic coverage, suitable for safety functions up to the highest performance level. Rated at 24 VDC, the relay uses solid-state enabling circuits rather than electromechanical contacts for the safety path, which eliminates contact wear and bounce in high-cycle applications. The two instantaneous contacts provide the switching output for the safety function. The spring-loaded (push-in) terminals accept solid wire 1x (20…16 AWG) or 2x (20…16 AWG) and stranded with or without ferrules, so the panel builder can land the safety circuit without screwdriver torque checks.

Integration and wiring — cascading, feedback, and start inputs

The relay includes a start input, a feedback input, and a safety switch input, allowing it to be wired into a standard safety chain: E-stop or guard switch on the safety input, feedback from a contactor or motor starter, and a start/reset button on the start input. Cascading design is supported, so multiple 3SK1112-2BB40 units can be linked to expand the number of safety zones without adding a separate safety PLC. The sensor input minimum on-time is 60 ms — short enough for most mechanical safety switches, but long enough to filter contact bounce. Operating frequency is rated at 2 000 1/h maximum, which covers typical machine cycle rates without derating. Electrical connection uses spring-loaded terminals (push-in) — strip length and ferrule sizing per the listed cross-sections: with core end processing 1x (0.5…1.0 mm²) or 2x (0.5…1.0 mm²); without core end processing 1x (0.5…1.5 mm²) or 2x (0.5…1.5 mm²).

Shock resistance is 10 g / 11 ms, and mounting position is any. EMC emitted interference meets IEC 60947-5-1, Class A — intended for industrial environments, not residential. Insulation voltage rated value is 50 V.

MPN
3SK1112-2BB40