The 3UG3522-1AL20: The 0.1–10 A range covers small motor circuits, pump protection, heater banks, or conveyor drives where you need to detect a loss of load (undercurrent) or a stalled rotor (overcurrent). The single-pole main circuit means it monitors one conductor only — fine for single-phase or DC circuits; for three-phase monitoring you'd need three units or a three-phase relay. The 1 CO contact is rated for AC 230 V control circuits; it can directly switch a PLC input or a contactor coil up to that voltage. The 22.5 mm width is the standard narrow housing for DIN-rail relays — fits alongside terminal blocks and other 22.5 mm modules without wasting panel width.

Siemens 3UG3522-1AL20 SIRIUS Monitoring Relay, 0.1-10A, AC 2
MPN 3UG3522-1AL20
Siemens SIRIUS 3UG3522-1AL20 monitoring relay, 22.5mm, undercurrent/overcurrent monitoring, 0.1-10A AC/DC, 1 CO contact, AC 230V 50/60Hz, screw connection.
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Mounting | Snap-on Mounting |
| Temp operating max | 50 °C |
| Temp operating min | -20 °C |
Product details
MPN
3UG3522-1AL20