Skip to main content
Siemens 3VA9267-0HC15

Siemens 3VA9267-0HC15 SENTRON Motorized Operating Mechanism,

MPN 3VA9267-0HC15
Active

synchronizable motor operator 24V DC incl. COM accessory for: 3VA2 100/160/250

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3VA9267-0HC15 specifications
ParameterValue
Depth162.8 mm
Width105 mm
Height118.7 mm

Product details

The Siemens SENTRON 3VA9267-0HC15 is a motorized operating mechanism with stored energy mechanism (SEO) designed for remote switching of 3VA2 molded case circuit breakers in the 100 A, 160 A, and 250 A frame sizes. It runs on 24 V DC control voltage and draws 300 VA operating apparent power to charge the spring mechanism, which then trips or closes the breaker on command. This is a panel-mount accessory that bolts onto the front of the 3VA2 breaker. The stored-energy design means the spring charges over roughly 0.08 s (make and break time typical) and releases independently of the control voltage — so even if the 24 V DC supply dips during closing, the mechanism still completes the stroke. That matters for applications where breaker position must be guaranteed regardless of control power quality.

The mechanism measures 105 mm wide, 118.7 mm high, and 162.8 mm deep. That depth includes the operator housing that protrudes forward from the breaker face — account for it in enclosure depth calculations, especially if the panel door has a cutout for the breaker rotary handle. The width matches the 3VA2 breaker front, so it does not increase the DIN-rail footprint. Stripped length for the control wiring is 7 mm — standard for screw-clamp terminals on this class of accessory. Strip to that length and no more; longer bare wire risks shorting against the mechanism housing.

Environmental range

The -40 °C floor covers cold storage or outdoor enclosures in northern climates; the 80 °C ceiling handles the heat rise inside a sealed panel near the breaker arc chamber. No derating curve is published for the stored-energy spring at temperature extremes, but the mechanism's mechanical nature means it is less thermally sensitive than electronic operators.

MPN
3VA9267-0HC15