Skip to main content
Siemens 4EP4000-1QS00

Siemens 4EP4000-1QS00 SIDAC Output Reactor, 15.5A 8000Hz

MPN 4EP4000-1QS00

Siemens SIDAC series, output reactor, 3-phase AC, 350V, 15.5A max, 8000 Hz, 0.7 mH, IP00, screw terminals, 4EP4000-1QS00.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

4EP4000-1QS00 specifications
ParameterValue
IP ratingIP00
Depth0.14 m
Width0.21 m
Height0.17 m

Product details

The Siemens 4EP4000-1QS00 is a 3-phase AC output reactor from the SIDAC series, rated for a maximum continuous current of 15.5 A and a rated frequency of 8000 Hz. It's designed to sit between a variable-frequency drive and the motor, smoothing the voltage spikes and limiting the rate of rise (dV/dt) that long cable runs or fast-switching IGBTs can cause. The 0.7 mH inductance and 350 V voltage class (per the description) tell you it's sized for a specific motor load impedance — not a generic filter. Screw terminals for the main circuit keep wiring straightforward for a panel builder.

The 8000 Hz rated frequency is the key number here — that's the switching frequency of the drive's output stage, not the motor's running speed. If your drive's IGBTs are switching at 8 kHz or below, this reactor is in its sweet spot. Push the carrier frequency higher and the core losses climb; you'd derate or look for a reactor rated for 12 or 16 kHz. The 15.5 A maximum is the thermal current limit at 40 °C ambient (the rated ambient temperature). That's the continuous RMS current the reactor can carry without exceeding Class B insulation temperature rise (130 °C total, per IEC 60085). If your motor draws 14 A full-load and the drive is sized for 15 A, this reactor is matched. The 65 W coil loss plus 45 W iron core loss — 110 W total — is heat that stays inside the panel, so factor it into your enclosure cooling calculation.

Dimensions: 0.21 m wide, 0.17 m tall, 0.14 m deep. IP00 open-frame. Screw terminals.

MPN
4EP4000-1QS00