Siemens 5SL4201-8

Siemens 5SL4201-8 SENTRON MCB, 2P D 1A 10kA

MPN 5SL4201-8
Active

Siemens SENTRON 5SL4201-8 miniature circuit breaker, 2-pole, D tripping characteristic, 1 A rated, 10 kA breaking capacity at 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL4201-8 specifications
ParameterValue
Poles2
IP ratingIP20
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

The Siemens 5SL4201-8 is a 2-pole miniature circuit breaker from the SENTRON series, rated 1 A with a D tripping characteristic and a 10 kA breaking capacity per both EN 60898 and IEC 60947-2. That D-curve means it tolerates the high inrush currents typical of motor loads, transformers, or solenoid banks — the magnetic trip threshold sits higher than a B or C curve, so nuisance tripping on startup is less likely. The 10 kA interrupting rating at 400 V AC tells you it can safely clear a fault up to that level without upstream fuses needing to act first, which simplifies coordination in a distribution board.

DIN-rail fit and panel integration

Two modular-width units wide (36 mm), 76 mm deep, 90 mm tall — it snaps onto standard DIN rail and occupies the same footprint as any other 2-pole SENTRON MCB. Mounting position is unrestricted, so you can orient it vertically or horizontally inside the enclosure without derating the thermal trip. The 70 mm installation depth leaves room behind the busbar stack in a typical 120 mm deep distribution board. IP20 with conductors connected, which is the norm for enclosed panel-mount breakers — not rated for washdown or outdoor exposure. Overvoltage category III and pollution degree 2 confirm it's intended for fixed-installation distribution boards, not portable equipment.

Thermal derating and ambient limits

The 1 A nominal rating holds at 30 °C ambient. At 40 °C it derates to 0.96 A, at 45 °C to 0.94 A, and at 55 °C to 0.9 A. If your panel runs hot — say next to a VFD or transformer — the actual continuous current the breaker can carry without nuisance tripping drops by roughly 4–10 %. The operating range spans -40 °C to 75 °C, so cold starts in unheated enclosures are fine; the storage limit is the same 75 °C maximum.