Siemens SENTRON 5SL4216-8 miniature circuit breaker, 2-pole, D tripping characteristic, 16 A rated current at 400 V AC, 10 kA breaking capacity, 2 MW.

$20.32 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL4216-8 specifications
ParameterValue
Poles2
IP ratingIP20
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

What the ratings mean for your panel

The Siemens 5SL4216-8 is a 2-pole SENTRON miniature circuit breaker with a D tripping characteristic, rated 16 A at 400 V AC. The D-curve means it tolerates inrush currents 10–20 times the rated current — designed for loads with high starting surges like small motors, transformers, or discharge lighting. The 10 kA breaking capacity (per EN 60898 and IEC 60947-2) is the fault current it can safely interrupt; in a 400 V panel this covers most residential and light commercial service-entrance scenarios. At 40 °C ambient the continuous rating derates to 14.78 A, and at 55 °C to 12.74 A — so if the breaker shares a crowded enclosure, size the load for the thermal curve, not the 30 °C nameplate.

Deployment context and integration

The 5SL4216-8 snaps onto standard DIN rail (2 MW wide at 36 mm) and can be mounted in any position — useful when panel layout is tight. Depth is 76 mm with 70 mm installation depth behind the panel face. IP20 with connected conductors means it's protected against finger contact but not washdown; keep it inside an enclosure. The housing is halogen-free and silicon-free, which matters for environments where outgassing can contaminate sensitive contacts or optics.

Selectivity and coordination note

Energy limitation class 3 means this breaker limits let-through energy to a defined level, which aids selective coordination with downstream devices. Overvoltage category III and pollution degree 2 are standard for fixed-installation distribution boards. The sealable design allows the installer to lock the toggle position — useful for lockout/tagout on a dedicated circuit.