Siemens 5SL4501-7

Siemens 5SL4501-7 SENTRON MCB, 1P+N, C-curve, 1 A, 10 kA

MPN 5SL4501-7
Active

Siemens SENTRON 5SL4501-7, miniature circuit breaker, 1P+N, C characteristic, 1 A rated, 230 V AC, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 2 MW units, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL4501-7 specifications
ParameterValue
Poles2
IP ratingIP20
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

What it is and where it goes

The Siemens 5SL4501-7 is a SENTRON miniature circuit breaker (MCB) with a 1P+N pole design — it switches the phase and monitors the neutral, but does not switch the neutral. Rated 1 A at 230 V AC with a C tripping characteristic, it breaks fault currents up to 10 kA per EN 60898 and IEC 60947-2. That 10 kA SCCR means it can safely interrupt a short-circuit up to that level without welding the contacts or cascading the fault upstream — critical for selectivity in a distribution board. It occupies 2 modular width units (36 mm) on a DIN rail and is rated IP20 with conductors connected, so it lives inside an enclosure, not on a washdown line.

What the ratings mean for fit

The C-curve means the magnetic trip operates at 5 to 10 times the rated current — so for a 1 A breaker, the instantaneous trip point is between 5 A and 10 A. That suits lighting, control transformers, and small motor loads with moderate inrush. The 10 kA breaking capacity at 230 V AC is standard for residential and light commercial distribution boards. Temperature derating is baked in: at 40 °C ambient the breaker carries 0.95 A, at 55 °C it drops to 0.86 A — so if the panel runs hot, size up one step. Power loss per pole is 1.2 W at rated current; in a crowded enclosure with several breakers, that heat adds up and affects the derating curve.

Panel integration notes

Mounts in any position on a 35 mm DIN rail. Depth is 76 mm overall; installation depth (behind the panel face) is 70 mm. The housing is halogen-free and silicon-free — relevant if the panel is in a clean room or a zone where outgassing matters. Sealable with a lockable cover or padlock accessory to prevent unauthorized switching. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be added on the right side without extra wiring space.