Skip to main content
Siemens 5SL4532-6

Siemens 5SL4532-6 SENTRON MCB, 32 A B-Curve 1P+N, 10 kA

MPN 5SL4532-6
Active

Siemens SENTRON 5SL4532-6 miniature circuit breaker, 1P+N, B-curve, 32 A, 230 V AC, 10 kA breaking capacity, 2 MW units wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL4532-6 specifications
ParameterValue
Poles2
IP ratingIP20
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

The Siemens 5SL4532-6 is a SENTRON miniature circuit breaker — a 1P+N, 32 A, B-curve MCB rated for 230 V AC single-phase circuits with a 10 kA breaking capacity per both EN 60898 and IEC 60947-2.

The 10 kA rating under both EN 60898 (domestic/residential standard) and IEC 60947-2 (industrial standard) means this breaker can safely interrupt fault currents up to 10,000 A at 230 V AC without welding its contacts or failing to clear — the same figure under both standards simplifies specification across mixed residential and light commercial panels.

Supplementary devices (shunt trip, auxiliary contacts, undervoltage release) can be snapped onto the side without removing the breaker from the rail.

Environmental and material specs

Halogen-free and silicon-free construction means off-gassing during a fault event won't produce corrosive halogen acids that attack nearby contacts or electronics — relevant for panels housing PLCs or sensitive controls.

Power loss and thermal considerations

At 32 A rated current, each pole dissipates 2.7 W in the hot operating state. In a 2-pole (1P+N) package that's 5.4 W total — modest enough that side-by-side mounting in a crowded DIN rail won't push the enclosure ambient above the 75 °C max, but worth checking if the panel is tightly packed with other heat sources.

How it sits against a sibling — 5SL4363-7

The closest functional peer in the SENTRON 5SL family is the 5SL4363-7 — a 3-pole, C-curve, 63 A unit rated at 400 V AC with the same 10 kA breaking capacity. The 5SL4532-6 is the smaller, single-phase version: 32 A, B-curve, 1P+N, 230 V, and 2 MW wide instead of 3 MW. If your BOM calls for a 32 A single-phase breaker with a faster trip curve for resistive loads, the 5SL4532-6 is the right pick; the 5SL4363-7 is for three-phase 63 A motor or distribution circuits where C-curve inrush handling is needed.