Skip to main content
Siemens 5SL6125-6

Siemens SENTRON 5SL6125-6 MCB, 1P, B, 25 A, 6 kA

MPN 5SL6125-6
Active

Siemens SENTRON miniature circuit breaker, 5SL6125-6, 1-pole, B characteristic, 25 A rated current, 6 kA breaking capacity per EN 60898, 230/400 V AC.

$2.37 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL6125-6 specifications
ParameterValue
Poles1
IP ratingIP20
Depth76 mm
Width18 mm
Height90 mm
Energy limitation class3

Product details

What this MCB does on the rail

The Siemens SENTRON 5SL6125-6 is a 1-pole miniature circuit breaker with a B tripping characteristic, rated 25 A at 30 °C and 400 V AC per EN 60898. Its 6 kA breaking capacity covers residential and light commercial distribution boards where the prospective short-circuit current stays under that threshold. The B curve means it trips between 3 and 5 times rated current — typical for resistive and general-purpose loads where inrush is modest. At 40 °C ambient the continuous rating drops to 23.48 A; at 55 °C it's 21 A, so derate if the panel runs hot. Single-pole format occupies one modular width (18 mm) on a DIN rail, and the IP20 rating with connected conductors is standard for enclosed distribution boards.

Physical fit and environment

Width 18 mm (one modular unit), depth 76 mm, height 90 mm — fits any standard 35 mm DIN-rail enclosure. Installation depth 70 mm leaves clearance for rear busbars. Mounting position any orientation; pollution degree 2 (non-conductive, occasional condensation). Temperature range -40 °C to 75 °C covers unheated utility rooms and outdoor-adjacent cabinets. Halogen-free and silicon-free construction matters for clean-room or high-reliability environments where outgassing can't be tolerated. Sealable terminals allow lockout/tagout compliance. Supplementary devices (auxiliary contacts, shunt trips, alarm switches) can be snapped on the right side.

Electrical ratings and coordination

Rated 25 A at 230/400 V AC, single-pole switching. Breaking capacity 6 kA per both EN 60898 and IEC 60947-2 — that's the same standard for residential and industrial coordination. Overvoltage category III (distribution level). Energy limitation class 3 means it limits let-through energy for downstream equipment protection. Mechanical endurance 10 000 operating cycles typical. Power loss 2.8 W per pole at rated current in hot state — factor into thermal calculations for multi-pole assemblies in compact enclosures.

MPN
5SL6125-6