Skip to main content
Siemens 5SM3314-6KK01

Siemens 5SM3314-6KK01 SENTRON RCCB, 40 A, 30 mA, Type A, Sho

MPN 5SM3314-6KK01

Siemens SENTRON 5SM3 series, Residual Current Operated Circuit Breaker (RCCB), 2-pole, Type A, short-time delayed, In: 40 A, 30 mA, Un AC: 230 V, 10 kA SCCR, DIN rail mount, 2 MW.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SM3314-6KK01 specifications
ParameterValue
Short circuit rating10 kA
Poles2
MountingDIN rail (REG)
Depth70 mm
Width36 mm
Height90 mm

Product details

The Siemens 5SM3314-6KK01 is a 2-pole SENTRON residual current operated circuit breaker (RCCB) rated for 40 A at 230 V AC, with a 30 mA trip threshold and Type A fault current detection. It carries a 10 kA short-circuit current rating and is designed as short-time delayed, meaning it tolerates brief surge currents — up to 3 kA rated surge current resistance — without nuisance tripping, which matters when feeding loads with capacitive inrush or downstream surge suppressors.

The 30 mA residual sensitivity and Type A waveform detection (AC sinusoidal plus pulsating DC fault currents) cover the majority of modern electronic loads — switched-mode power supplies, variable-speed drives, LED drivers — that generate pulsating DC leakage. Standard Type AC RCCBs may not trip on those waveforms; Type A is the baseline for commercial and light industrial panels today. The short-time delayed characteristic (letter K or short-time delayed designation) allows the device to ride through brief earth-fault current pulses up to 3 kA without tripping, which prevents coordination issues with surge protective devices or capacitor switching banks upstream. It is not a general-purpose instantaneous RCCB — fit it where you need selectivity against transient leakage. Rated 40 A at 230 V AC, this unit covers feeder circuits up to that continuous load.

Mounts on DIN rail (REG profile) in any position, occupying 2 width units (36 mm). Installation depth is 70 mm — check enclosure depth clearance; the body projects 70 mm from the rail. Silicon-free construction is specified — relevant for environments where silicone outgassing can contaminate contacts or optics.

MPN
5SM3314-6KK01