Siemens 5SM3344-0KL

Siemens 5SM3344-0KL SENTRON RCCB, 4P, 40 A, 30 mA, 400 V AC

MPN 5SM3344-0KL

Siemens SENTRON 5SM3 series, RCCB, 4-pole, type AC, In: 40 A, IΔn: 30 mA, Un: 400 V AC, 10 kA SCCR, DIN rail mount, N left.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SM3344-0KL specifications
ParameterValue
Short circuit rating10 kA
Poles4
MountingDIN rail (REG)
Temp operating max45 °C
Temp operating min-5 °C

Product details

The Siemens 5SM3344-0KL is a 4-pole SENTRON residual current operated circuit breaker (RCCB), type AC, rated 40 A with a 30 mA trip threshold at 400 V AC — the standard residential and light commercial ground-fault protection package for three-phase networks where neutral is brought in on the left side of the device. The 30 mA sensitivity is the common touch-safe threshold per IEC 60364, meaning it clears leakage currents that would be hazardous to a person making contact with an energized enclosure. It is an instantaneous (non-time-delayed) design — no intentional delay before tripping on a ground fault — so it responds immediately to sinusoidal AC residual currents at the mains frequency of 50 Hz.

The 30 mA trip threshold is the standard for personal protection against electric shock; it will not coordinate with a 30 mA upstream RCCB — if selectivity is needed between two RCCBs, the downstream unit must be a time-delayed (S-type) or a lower-threshold device. Ambient temperature range of -5 to +45 °C covers most indoor panel environments, but at sustained temperatures above 40 °C the continuous current rating should be derated per the manufacturer's thermal curve — the 40 A rating is at a reference ambient, typically 30 or 35 °C.

Snaps onto standard DIN rail (REG profile), occupies 4 width units (roughly 72 mm), and installs in any orientation — top or bottom feed, horizontal or vertical rail, no restriction. Installation depth is 70 mm from the rail — fits flush in a standard 125 mm deep distribution board; check the gland plate clearance if you're running conductors behind the device. Terminals accept solid or stranded conductors from 1.5 to 25 mm² — covers everything from a 2.5 mm² lighting circuit tail up to a 16 mm² feeder; tighten to 2.5 to 3 N·m with a screwdriver, no special torque tool needed. The N-left variant means the neutral pole is on the left side of the device when viewed from the front — if you're replacing an existing RCCB that has neutral on the right, you'll need to swap the incoming and outgoing conductors or use a different variant.

MPN
5SM3344-0KL