Skip to main content
Siemens 5SM3416-6KL

Siemens 5SM3416-6KL SENTRON RCCB, 2-pole Type A, 63A 100mA 2

MPN 5SM3416-6KL

Siemens SENTRON 5SM3 series RCCB, 2-pole Type A, In 63 A, IΔn 100 mA, Un AC 230 V, N left, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SM3416-6KL specifications
ParameterValue
Short circuit rating0 kA
Poles2
MountingDIN rail (REG)
Temp operating max45 °C
Temp operating min-25 °C
Depth70 mm
Width36 mm
Height90 mm

Product details

The Siemens 5SM3416-6KL is a SENTRON residual current operated circuit breaker (RCCB), 2-pole, Type A, rated 63 A at 230 V AC with a 100 mA trip threshold.

The 63 A rated current at 50 Hz means this RCCB carries the full load of a typical residential or light commercial submain — think a lighting and general-purpose socket circuit feeding a small workshop or a panel in a pump house. The 100 mA residual trip is the slower, ground-fault protection level, not the 30 mA personal-shock threshold; it's meant for equipment protection or circuits where nuisance tripping from leakage is a concern, like older motors or long cable runs. Type A detection catches pulsating DC fault currents on top of sinusoidal AC — that covers modern electronics with half-wave rectifiers, switched-mode power supplies, and variable-speed drives downstream. If your line has VFDs or LED drivers, Type A is the right call over Type AC. The instantaneous design means no intentional time delay; it trips as fast as the fault current lets it. Ambient temperature range of -25 to +45 °C and storage down to -40 °C means it handles unheated electrical rooms and outdoor enclosures in most climates, though you'll want to keep the panel ventilated if it's sitting in direct sun.

Mounts on DIN rail (REG) in any position — the device is 36 mm wide (2.5 width units), 90 mm tall, and 70 mm deep, which is a standard footprint for a 2-pole RCCB. The screw terminals accept 1.5 to 25 mm² solid or stranded copper, tightened to 2.5 to 3 N·m. That's enough lug for a 25 mm² incoming feed and daisy-chaining through the busbar system. Supply can land top or bottom, which saves head-scratching when you're retrofitting into an existing board where the feed comes up from the bottom.

MPN