Skip to main content
Siemens 5SM3646-8KK12

Siemens 5SM3646-8KK12 SENTRON RCCB, 63A, 300mA, 4P, Type A S

MPN 5SM3646-8KK12

Siemens SENTRON 5SM3646-8KK12, 4-pole RCCB, Type A selective, 63 A, 300 mA, 400 V AC, SIGRES variant for harsh ambient conditions.

$561.48 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SM3646-8KK12 specifications
ParameterValue
Poles4
MountingDIN rail (REG)
Temp operating max45 °C
Temp operating min-25 °C
Depth77 mm
Width72 mm
Height90 mm

Product details

The Siemens 5SM3646-8KK12 is a 4-pole residual current operated circuit breaker (RCCB) from the SENTRON 5SM3 series, designed as a Type A selective device with a rated tripping residual current of 300 mA and a rated current of 63 A at 400 V AC. The selective design (short-time delayed) means it coordinates with downstream RCCBs — it holds during a fault long enough for the downstream device to clear, isolating only the faulty branch. This avoids a full-panel blackout on a single branch fault.

Rated at 63 A continuous and 300 mA trip threshold: this is a feeder or submain RCCB, not a final-circuit device. The 300 mA threshold provides earth-leakage protection while tolerating the natural leakage of long cable runs and multiple connected loads. Rated impulse withstand current of 1 kA (surge current resistance) means it survives the inrush from capacitor banks or nearby lightning-induced surges without nuisance tripping — important for industrial panels with power-factor correction or long overhead supply lines. Mechanical service life of 10 000 switching cycles typical — adequate for a protective device that operates infrequently; not a switching contactor for daily cycling.

Mounting position any orientation, installation depth 70 mm. Terminals accept solid or stranded copper from 1.5 mm² up to 25 mm², with a tightening torque of 2.5 to 3 N·m.

This is the SIGRES variant, specified for harsh ambient conditions — the standard 5SM3 RCCB without the SIGRES suffix is the standard-duty version. The SIGRES designation means the internal components and housing are selected for higher resistance to humidity, temperature cycling, and corrosive atmospheres, per the manufacturer's SIGRES specification.

MPN