Skip to main content
Siemens 5SP4291-6

Siemens 5SP4291-6 SENTRON MCB, 2-Pole, B Curve, 100 A, 10 kA

MPN 5SP4291-6
Active

Siemens SENTRON 5SP4291-6, 2-pole miniature circuit breaker, B tripping characteristic, 100 A rated current at 30 °C, 10 kA breaking capacity per EN 60898, 400 V AC.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SP4291-6 specifications
ParameterValue
Poles2
Depth76 mm
Width54 mm
Height90 mm

Product details

Ratings and what they mean for fit

The 5SP4291-6: The 100 A rating at 30 °C is the headline figure, but the derating curve matters when the breaker lives in a warm enclosure. Per the datasheet, at 40 °C it carries 95 A, at 50 °C it drops to 89.5 A, and at 60 °C it is down to 84 A. If your panel ambient runs above 30 °C, size the load against the derated value, not the 30 °C number. The B characteristic (3–5× In magnetic trip) is the standard choice for resistive and general-purpose loads where inrush is low — lighting, heating, distribution subfeeds. It is not intended for motor starting or transformer primary circuits that draw a higher inrush; those call for a C or D curve. The 10 kA breaking capacity per EN 60898 at 400 V AC means this breaker can safely interrupt a fault current up to 10 kA without welding or rupturing. That is adequate for most commercial and light industrial distribution boards fed by a transformer of typical impedance. If the prospective short-circuit current at the installation point exceeds 10 kA, you need a higher-rated device or a current-limiting upstream breaker.

Mounting and integration

Mounts on DIN rail (EN 60715) or via screw fixing — either works, and the mounting position is unrestricted. The breaker occupies 3 modular width units (54 mm) on the rail, with an installation depth of 70 mm and an overall depth of 76 mm. Tunnel terminals at both top and bottom accept the conductors; touch protection is built in per the design. The housing is halogen-free and silicon-free, which matters for panels in clean-room or semiconductor-adjacent environments where outgassing can contaminate optics or contacts. Pollution degree 3 (conductive pollution or dry non-conductive pollution that becomes conductive due to condensation) is the rating — typical for industrial control panels not in a sealed, climate-controlled room. IP20 with connected conductors, IP40 at the handle area with the distribution cover fitted. That is standard for enclosed distribution boards; the breaker itself is not rated for washdown or outdoor exposure without an enclosure.

Environmental and mechanical endurance

Rated for ambient temperatures from -40 °C to 75 °C, with a maximum 95% relative humidity. Shock resistance per IEC 60068-2-27 is 150 m/s² at 11 ms half-sine; vibration resistance per IEC 60068-2-6 is 50 m/s² at 25 to 150 Hz and 60 m/s² at 35 Hz (4 seconds). These figures confirm it can handle the mechanical stress of shipping and normal panel vibration from contactors or drives mounted on the same rail.