Skip to main content
Siemens 5SU9406-0KK20

Siemens 5SU9406-0KK20 SENTRON RCD Circuit Breaker, 20 A, B C

MPN 5SU9406-0KK20

Siemens SENTRON 5SU9 series, RCD-operated circuit breaker (RCBO), 1P+N, 2-pole, 20 A rated current, B tripping characteristic, 6 kA breaking capacity per EN 60898 and IEC 60947-2, 18 mm width, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SU9406-0KK20 specifications
ParameterValue
Poles2
Temp operating max45 °C
Temp operating min-25 °C
Depth77 mm
Width18 mm
Height125 mm

Product details

The Siemens 5SU9406-0KK20 is a SENTRON-series RCD-operated circuit breaker (RCBO) that combines overcurrent protection and residual current protection in a single 18 mm wide module. The breaking capacity is 6 kA per both EN 60898 and IEC 60947-2, which certifies its ability to safely interrupt faults up to that level in a 230/400 V AC distribution panel. This is a 1P+N device — it switches the live conductor and monitors the neutral for residual current, but does not switch the neutral. The fault current type is AC (sinusoidal), and the design is instantaneous (no intentional time delay), so it responds immediately to earth leakage.

The 20 A rating applies at 30 °C ambient. At 40 °C the continuous current must be derated to 18.8 A; at 45 °C to 18.2 A; at 50 °C to 17.4 A; and at 55 °C to 16.2 A. The operating ambient range is -25 to +45 °C, so the 45 °C derating figure is the relevant maximum for a panel running near its thermal limit. Storage temperature spans -40 to +75 °C. Power dissipation is 0.75 W at rated load, which is low enough that grouping multiple units in an enclosure does not require special ventilation beyond standard panel design. The energy limiting class is 3, indicating good let-through energy limitation for downstream equipment protection.

Height is 125 mm. Supply can enter from either the top or bottom terminals, simplifying busbar routing in a crowded panel. Terminals accept solid conductors from 0.75 to 35 mm² and stranded conductors from 0.75 to 35 mm². Touch protection is provided per the product feature listing.

The 5SU9406-0KK20 is designed to EN 60898 (for household and similar installations) and IEC 60947-2 (for low-voltage switchgear and controlgear), with a 6 kA rated short-circuit capacity under both standards.

MPN