Skip to main content
Siemens 5SY3203-7

Siemens 5SY3203-7 SENTRON MCB, 2P C-Curve 3A 4.5kA

MPN 5SY3203-7

Siemens SENTRON 5SY3 series, 5SY3203-7 miniature circuit breaker, 2-pole, C tripping characteristic, 3 A rated current at 400 V AC, 4.5 kA per EN 60898.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY3203-7 specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max55 °C
Temp operating min-25 °C
Depth76 mm
Width36 mm
Height90 mm

Product details

Siemens 5SY3203-7 — 2-pole C-curve MCB for 3 A branch circuits

The Siemens 5SY3203-7 is a 2-pole miniature circuit breaker from the SENTRON 5SY3 series, rated 3 A at 400 V AC with a C tripping characteristic. At 3 A it handles branch circuits feeding control transformers, contactor coils, or signal-conditioning supplies in a panel. Breaking capacity is rated at 4.5 kA per EN 60898 and 6 kA per IEC 60947-2 at 400 V AC; for DC circuits it's rated 15 kA at 72 V DC per IEC 60947-2, and 5 kA at 400 V AC per UL 1077 / CSA C22.2 No.235. That covers most industrial panel fault currents below a main distribution board.

No last-time-buy or phase-out notice is on record. For BOM-freeze planning, the 5SY3 series has broad installed base and the form factor (2-module wide, DIN-rail mount) is industry-standard, so any future replacement would share the same footprint.

Combined top and bottom terminals accept solid or stranded conductors from 0.75 mm² up to 35 mm² — a wide range that covers both control-circuit wiring (1.5 mm²) and feeder tails (10–16 mm²). The terminals are touch-protected (IP20 with conductors connected) and sealable for panel lock-out/tag-out procedures.

Coordination and selectivity note

Energy limiting class 3 means the breaker limits let-through energy well — useful for downstream component protection. Overvoltage category III suits fixed-installation distribution boards. The 5SY3 design is the standard 5SY platform with C-curve; the 5SY6 series (higher breaking capacity) exists for applications needing more fault-current headroom, but the 5SY3203-7 covers the common 3 A branch with adequate interrupting ratings for most sub-distribution panels.

MPN
5SY3203-7