Skip to main content
Siemens 5SY5214-7CC11

Siemens 5SY5214-7CC11 SENTRON MCB, 2P C 0.3A, 440V DC Railwa

MPN 5SY5214-7CC11

Siemens SENTRON 5SY5214-7CC11, miniature circuit breaker, 2-pole, C-trip characteristic, 0.3 A rated current, 440 V DC, 10 kA breaking capacity at DC per IEC 60947-2, designed for railway applications.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY5214-7CC11 specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width36 mm
Height90 mm

Product details

The 0.3 A rating is unusually low for a 2-pole MCB; this part protects a specific low-current DC circuit — think auxiliary control loops, signaling supplies, or battery-monitoring branches in a rail vehicle. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) matches the mechanical shock profile of traction and under-car equipment.

Fastens via the quick-assembly system; mountable in any position. IP20 with connected conductors, so it is intended for a protected enclosure, not open-rack. Sealable terminals and halogen-free / silicon-free construction are specified.

MPN
5SY5214-7CC11