Siemens SENTRON 5SY6163-7CC MCB, 63 A, C-Curve, 1-Pole, 6 kA

MPN 5SY6163-7CC

Siemens SENTRON miniature circuit breaker, 5SY6163-7CC, 1-pole, 63 A, C characteristic, 6 kA per EN 60898, 18 mm width.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY6163-7CC specifications
ParameterValue
Poles1
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width18 mm
Height90 mm
Energy limitation class3

Product details

What it is — and what the ratings mean for fit

The Siemens SENTRON 5SY6163-7CC is a 1-pole miniature circuit breaker rated 63 A at 35 °C with a C tripping characteristic, meaning it handles moderate inrush currents from motor starters or transformers without nuisance tripping while still protecting branch circuits. Its 6 kA breaking capacity per EN 60898 is the standard for residential and light commercial distribution boards — adequate for most sub-distribution panels where the prospective short-circuit current stays under that threshold. The C-curve triggers between 5 and 10 times rated current, so it's the typical choice for general-purpose loads, not for high-inrush transformers (that's a D-curve job) or purely resistive loads (B-curve). At elevated panel temperatures the breaker derates: 59.22 A at 40 °C, 57.27 A at 45 °C, 55.19 A at 50 °C, and 53.05 A at 55 °C. If your enclosure runs hot — say a packed DIN rail in a non-ventilated cabinet — size the upstream protection for the derated value, not the 35 °C sticker.

Panel fit and mounting

Occupies 1 modular width unit (18 mm) on a DIN rail, with a depth of 76 mm and an installation depth of 70 mm behind the panel surface. The quick-assembly system snaps onto standard EN rail; mounting position is any, so vertical or horizontal rail orientation works. Touch protection is built in, and the terminals are combined top and bottom — wire from either direction without flipping the breaker. Sealable for tamper-proof installations (e.g., metering cabinets or rental panels). Halogen-free and silicon-free construction matters for environments sensitive to outgassing — clean rooms, medical, or semiconductor support areas.

MPN
5SY6163-7CC