Skip to main content
Siemens 5SY6520-7CC

Siemens 5SY6520-7CC SENTRON MCB, 20 A, C-Curve, 2-Pole, 6 kA

MPN 5SY6520-7CC

Siemens SENTRON 5SY6520-7CC miniature circuit breaker, 20 A, C-curve, 2-pole (1P+N), 6 kA per EN 60898, 76 x 36 x 90 mm.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SY6520-7CC specifications
ParameterValue
Poles2
IP ratingIP20
MountingQuick assembly system
Temp operating max75 °C
Temp operating min55 °C
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

20 A C-curve MCB for panel protection

The Siemens 5SY6520-7CC is a SENTRON miniature circuit breaker rated 20 A at AC with a C tripping characteristic, configured as 2-pole (1P+N). The C-curve means it trips at 5 to 10 times rated current — suited for mixed resistive and moderate inductive loads where inrush is present but not extreme, such as contactor coils, small motor circuits, or general distribution subfeeds in industrial panels. Breaking capacity is 6 kA per EN 60898 — adequate for most low-fault industrial and commercial sub-distribution boards where the prospective short-circuit current stays under that threshold. For UL 1077 / CSA C22.2 No. 235 recognition, the interrupting rating is 5 kA, so verify the available fault current if the panel carries a UL label.

Panel integration and environmental fit

Occupies 2 modular width units (36 mm) on a DIN rail, with a quick-assembly fastening system and any mounting position. Depth is 76 mm; installation depth 70 mm. The IP20 rating (with connected conductors) is standard for enclosed distribution boards — not for wet or washdown zones. Ambient operating range spans -40 °C to 75 °C, with derated current values above 40 °C: 18.8 A at 40 °C, 17.52 A at 50 °C, 16.84 A at 55 °C. Combined terminal top and bottom, touch protection, and pollution degree 3 (conductive pollution or dry non-conductive pollution that becomes conductive due to condensation — typical in industrial enclosures without climate control). Halogen-free and silicon-free construction matters for environments sensitive to outgassing, such as clean rooms or sealed control cabinets near sensitive electronics.

MPN
5SY6520-7CC