Skip to main content
Siemens 6ES7518-4FP00-3AB0

Siemens 6ES7518-4FP00-3AB0 CPU 1518F-4 PN/DP, 32 KB I/O

MPN 6ES7518-4FP00-3AB0

Siemens S7-1500 CPU 1518F-4 PN/DP, failsafe controller, 32 kbyte input/output process image, PROFINET IRT with MRP, 1 Gbps on X3, RS-485, -40 to 70 °C ambient.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

6ES7518-4FP00-3AB0 specifications
ParameterValue
Product typeHardware clock
Depth129 mm
Width175 mm
Height147 mm
Backup time6 wk; At 40 °C ambient temperature, typically
Screen diagonal6.1 cm

Product details

Failsafe CPU with PROFIsafe V2.4/V2.6

The Siemens 6ES7518-4FP00-3AB0 is a CPU 1518F-4 PN/DP combining standard and failsafe logic on one controller. It supports FBD and LAD programming including failsafe blocks, and runs PROFIsafe V2.4 or V2.6 for safety-related communication over PROFINET. The process image is 32 kbyte for inputs and 32 kbyte for outputs, which sets the deterministic I/O data volume per bus cycle. This is the ceiling for the number of fast I/O points you can map without additional backplane communication.

PROFINET with MRP and 1 Gbps uplink

The CPU has three PROFINET ports: two at 100 Mbps for ring or line topology, and one dedicated X3 interface that supports 1000 Mbps for high-speed uplink to a plant network or SCADA server. MRP is supported with the CPU acting as Automanager per IEC 62439-2 Edition 2.0, Manager, or Client — no external switch needed for ring redundancy. IRT is not available on this CPU, so deterministic motion control over PROFINET is not possible. For applications requiring isochronous real-time, the CPU 1518-4 PN/DP (non-F variant) is the correct choice.

Extended temperature and RS-485 interface

The RS-485 interface on X4 supports Modbus RTU or point-to-point communication, useful for connecting legacy drives or remote I/O without an additional communication module. Up to eight communication modules (CMs or CPs) can be inserted for PROFIBUS, additional PROFINET, or Ethernet networks. The hardware clock maintains time across power cycles, and I&M data (I&M0 to I&M3) is supported for asset management.

Integrated PID and web server

Two integrated PID controllers are available: with optimisation for temperature loops, and for valve positioning. The CPU also hosts a web server with standard and user-defined pages accessible via HTTP and HTTPS, plus SNMP for network monitoring.

MPN
6ES7518-4FP00-3AB0