Skip to main content
Omron E5EC-CQ4A5M-009

Omron E5EC-CQ4A5M-009 Temperature Controller, 100-240VAC

MPN E5EC-CQ4A5M-009
Active

Omron E5EC series process/temperature controller, 100-240VAC, 4 relay + analog + voltage (SSR) outputs, RS-485 CompoWay/F & Modbus, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-CQ4A5M-009 specifications
ParameterValue
SeriesE5EC
Supply voltage100 to 240VAC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

What this controller does on your panel

The Omron E5EC-CQ4A5M-009 is a 1/4 DIN panel-mount process and temperature controller that accepts RTD and 13 thermocouple types (B, E, J, K, L, N, PLII, R, S, T, U, W) plus 0-20 mA and 0-10 VDC analog inputs, covering a span from -200°C to 2300°C. Output stage combines four relay outputs, one analog output, and a voltage output for an external SSR. The RS-485 port speaks both CompoWay/F and Modbus, so it drops into existing PLC networks without a protocol converter. The IP66-rated front panel means it handles washdown in food or beverage lines — the electronics behind the panel stay dry.

What the output mix buys you

Compared to the relay-only E5EC-RR4A5M-009 (six relay outputs, no analog or SSR drive), this CQ4A5M-009 trades two relays for an analog output and a dedicated SSR voltage output — the right choice if you need to retransmit the process value to a recorder or drive a high-cycle solid-state contactor. Against the QQ4A5M-010 (four relay plus two SSR voltage outputs), this unit adds the analog channel while keeping four relays — a middle ground for applications needing both a 4-20 mA retransmit and multiple on/off stages.

Panel cutout is 92.00 mm x 45.00 mm. The tri-color LCD shows four characters per row across three rows, with the top row at 0.710" (18.00 mm) for the process value — readable from across a machine cell. Event input and heater fault detection are built in, so you can trigger a setpoint change from a dry contact or monitor a heater current without an add-on module.

MPN
E5EC-CQ4A5M-009