Skip to main content
Omron E5EC-TQQ4A5M-010

Omron E5EC-TQQ4A5M-010 Process Controller

MPN E5EC-TQQ4A5M-010
Active

Omron E5EC-T, Process/Temperature Controller, 100~240VAC, Relay (4) + Voltage (External SSR) (2) outputs, LCD Tri-Color, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-TQQ4A5M-010 specifications
ParameterValue
SeriesE5EC-T
Output signalRelay (4), Voltage (External SSR) (2)
Supply voltage100 to 240VAC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

What this controller brings to the panel

The Omron E5EC-TQQ4A5M-010 is a process and temperature controller from the E5EC-T series, built to handle both RTD and thermocouple inputs — type B, E, J, K, L, N, PLII, R, S, T, U, W — plus 0–20 mA or 0–10 VDC linear signals. That input range spans -200°C to 2300°C, so it covers cryogenic monitoring right up to high-temp furnace loops without swapping modules. Outputs are split: four relay outputs for on/off or alarm duties, plus two voltage-pulsed outputs for driving external SSRs. That SSR pair is what makes this controller a good fit for a heater zone where you want zero mechanical wear on the switching element — the relays handle the event flags and the voltage outputs fire the power stage. The control method gives you a choice between simple on/off and full proportional (PID) with auto-tune. For a process that needs to hold a setpoint without overshoot — say a plastic extruder barrel or a heat-treat oven — the PID loop is what you commission first. The on/off mode is there for level alarms or simple batch heaters where a deadband is acceptable.

Panel fit and environmental sealing

Mounts in a rectangular panel cutout 92.00 mm x 45.00 mm and secures with screw terminals. The front face carries an IP66 rating. If the panel sees direct radiant heat from a kiln or a dryer, keep the controller below that upper bound — the spec is for ambient at the controller, not the process temperature.

Built-in diagnostics: heater fault detection and event input

Heater fault detection is included — it monitors current draw on the load side and flags a broken heater or a failed SSR. That's a practical line-down saver: instead of waiting for the process temperature to drift, the controller tells you the heating circuit has failed on the next cycle. The event input lets an external contact (a limit switch, a safety interlock, a remote start signal) change the controller's behavior — switch between two setpoints, hold the output, or trigger a ramp-soak profile. That keeps the logic in the controller rather than forcing a PLC to handle every mode change.

MPN
E5EC-TQQ4A5M-010