Skip to main content
Omron K8AC-H22CN-FLK

Omron K8AC-H22CN-FLK Heater Element Detector, 2-22A, RS-485

MPN K8AC-H22CN-FLK
Active

Omron K8AC-H22CN-FLK Heater Element Detector, K8AC-H series, input range 2 ~ 22A, solid-state outputs (2), RS-485 CompoWay/F, DIN rail mount, spring terminal, 85-264VAC supply.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

K8AC-H22CN-FLK specifications
ParameterValue
SeriesK8AC-H
Output signalSolid State (2)
Display typeLED - Red Characters
Product typeHeater Element Detector
Supply voltage85 to 264VAC
ProtocolRS-485 (CompoWay/F)
MountingDIN Rail
Temp operating max55 °C
Temp operating min-10 °C
Weight0.441 lb (200.03 g)
PackageBulk
Control methodOn/Off

Product details

Heater Element Detector — 2 to 22 A Sensing, RS-485 CompoWay/F

The K8AC-H22CN-FLK is a dedicated heater element detector from Omron's K8AC-H series, designed to monitor current draw in resistive heater loads and signal a fault when the current drops below a set threshold — a common failure mode in heated nozzles, extruder bands, and immersion heaters. Its input range spans 2 to 22 A, covering the typical current draw of single- and three-phase heater circuits in injection molding, packaging, and industrial oven applications.

DIN Rail Integration and Panel Wiring

Mounts on standard DIN rail with spring-clamp terminals — no screw torque to verify, just strip the wire and push in. The spring termination saves time on panel builds and holds up better under vibration than screw terminals. Powered from 85 to 264 VAC, so it runs directly off the control transformer without a separate 24 VDC supply. The wide input range covers 100 V, 110 V, 200 V, and 240 V line voltages common in industrial panels globally.

Outputs and Communication

Two solid-state outputs provide the alarm and fault signals — one typically wired to the PLC digital input for the heater alarm, the other to a local beacon or the machine safety circuit. RS-485 communication using Omron's CompoWay/F protocol lets the PLC or SCADA poll the detector for the actual current reading, not just the alarm status. The 4-digit red LED display shows the live current value on the panel door. Control method is On/Off — the detector compares the sensed current against a setpoint and switches the outputs when the current falls below the threshold. No PID loop here; this is a dedicated watchdog for heater integrity.

Sourcing and Lifecycle

Quoted to order against the BOM quantity. Availability and current pricing confirmed at RFQ through independent distribution channels.