Siemens 3RK1308-0CE00-0CP0

Siemens SIMATIC 3RK1308-0CE00-0CP0 Fail-Safe DOL Starter, 55

MPN 3RK1308-0CE00-0CP0
Active

Siemens SIMATIC fail-safe direct-on-line starter, 4 via 3DI/LC module, adjustable trip class, PROFINET and PROFIBUS DP, 55 kA at 400 V, pluggable in BaseUnit.

$289.56 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RK1308-0CE00-0CP0 specifications
ParameterValue
Mountingpluggable in BaseUnit
Depth150 mm
Width30 mm
Height142 mm
Trip classCLASS OFF / 5 / 10 adjustable

Product details

Fail-safe DOL starter with integrated safety logic

The Siemens SIMATIC 3RK1308-0CE00-0CP0 is a fail-safe direct-on-line starter that integrates a 4 via 3DI/LC module — meaning it handles up to four safety-related inputs via three digital inputs and a load-circuit channel, all in a single 30 mm-wide housing that plugs into a BaseUnit on the DIN rail. The adjustable trip class (CLASS OFF / 5 / 10) lets you match the overload curve to the motor's starting profile: CLASS OFF for solid-state or soft-start applications, CLASS 5 for fast-cycling loads like conveyors, CLASS 10 for standard induction motors.

Safety-rated switching with B10d data

With a B10d value of 910 000 cycles, this starter is suited for safety circuits where the probability of dangerous failure per demand must be quantified — the figure represents the number of cycles until 10% of the population fails dangerously, used in SIL/PL calculations per IEC 61508 and EN ISO 13849. The safe state is load circuit open, and the ON-delay time is 35 ms with OFF-delay adjustable from 35 to 50 ms, giving the control system predictable response timing for guarding applications.

Network-ready for PROFINET and PROFIBUS

Both PROFINET and PROFIBUS DP protocols are supported natively, so this module drops into either an IO-controller or a classic DP master architecture without a gateway. The input process data is 4 bytes and output data is 2 bytes, mapping directly to the safety-related I/O and status words in the controller's address space.

Mounting position can be vertical or horizontal, but derating applies for horizontal orientation. Vibration resistance is 15 mm at 6 Hz and 2g up to 500 Hz; shock resistance is 6g for 11 ms.

MPN
3RK1308-0CE00-0CP0