Skip to main content
Siemens 5SL6201-7

Siemens 5SL6201-7 SENTRON MCB, 2-Pole C-Curve 1A 6kA

MPN 5SL6201-7
Active

Siemens SENTRON 5SL6201-7, miniature circuit breaker, 2-pole, C-curve, 1 A, 6 kA, 400 V AC.

$13.97 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

5SL6201-7 specifications
ParameterValue
Poles2
IP ratingIP20
Depth76 mm
Width36 mm
Height90 mm
Energy limitation class3

Product details

What the ratings mean for fit

The Siemens 5SL6201-7 is a SENTRON miniature circuit breaker (MCB) rated 1 A with a C-curve tripping characteristic, meaning it is designed for moderate inrush loads such as lighting circuits, small transformers, and control transformers where the start-up current is several times the rated current before the thermal-magnetic trip clears it. The 6 kA breaking capacity (rated both per EN 60898 and IEC 60947-2) tells you it can safely interrupt a fault current up to 6 kA at 400 V AC without welding or arcing over — that is the standard residential and light-commercial fault level for most European distribution boards. Two poles (2P) switch both line conductors, so this is the right choice for single-phase 230 V circuits where you need disconnection on both poles, or for 400 V two-phase loads.

Panel integration and mounting

The 5SL6201-7 occupies 2 modular width units (36 mm total) on a DIN rail, with a depth of 76 mm and height of 90 mm. It snaps onto any standard 35 mm DIN rail and can be mounted in any position. The IP20 rating (with connected conductors) means it is protected against finger contact but not against moisture — standard for inside a distribution board or enclosure. The housing is halogen-free and silicon-free, which matters if the panel is in a clean-room or a location where outgassing could contaminate sensitive equipment. Installation depth is 70 mm, so plan for that behind the DIN rail.

Environmental and compliance

Rated for ambient temperatures from -40 °C to +75 °C, so it handles both cold storage areas and hot enclosure interiors. Overvoltage category III and pollution degree 2 are standard for fixed-installation distribution boards. The mechanical service life is 10,000 operating cycles typical — adequate for normal switching duty but not intended for frequent on/off control of motor loads (that is what a contactor is for). Power loss is 1.2 W per pole at rated current in hot operating state, useful for thermal calculations in a dense panel.

MPN
5SL6201-7