Fuji FRN0004G2S-4GU FRENIC-Eco VFD, 2 hp, 3.7 A, 380-480 VAC

MPNFRN0004G2S-4GU

Fuji Electric FRENIC-Eco series, FRN0004G2S-4GU, 2 hp VFD, 3.7 A output, 380-480 VAC three-phase input, NEMA 1 open enclosure, active production.

$663.61Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

FRN0004G2S-4GU — Approvals
ParameterValue
Standards complianceUL508C, C22.2 No.14, EN50178-1997

Product details

The Fuji FRN0004G2S-4GU is a 2 hp variable-frequency drive from the FRENIC-Eco series, rated for 3.7 A continuous output on a three-phase 380-480 VAC supply. Input voltage tolerance is +10% / -15%, so it holds regulation through moderate sags common on industrial lines. Output frequency spans 0.1 to 120 Hz, covering standard induction motors and some high-speed spindle applications. Starting torque is 50% at 1 Hz — enough to break away a loaded conveyor or fan without oversizing. Enclosure is NEMA 1 (open type), meaning it is intended for indoor panel mounting where falling dirt and drips are the only contaminants. The heat-sink style (listed as Style: Heat Sink) indicates the power stage relies on external airflow — plan for clearance above and below the drive, and keep ambient below 40 °C for full current rating.

I/O and control

The drive provides 7 digital inputs and 3 analog inputs, plus 5 digital outputs and 2 analog outputs. Control is via keypad or remote contact closure; the keypad shows motor speed with percent, alarm code, menu, and function code on a combined LCD/LED display. Digital readout also cycles through output frequency, current, and voltage. No Ethernet port is included, so communication is limited to the onboard I/O and any optional serial card (not listed here).

Overall dimensions: 10-1/4 in high, 5-7/8 in wide, 6-3/8 in deep. The NEMA 1 enclosure has no gland plate — conduit knockouts or a separate junction box are needed for field wiring. Mounting footprint is standard for this power class; allow 4 inches of free air above and below for convection cooling.

Frequently asked questions

What is the output power and current rating?

Maximum output power is 2 hp, with a maximum output current of 3.7 A at 480 VAC output.

What input voltage range does it accept?

Input voltage range is 380-480 VAC three-phase, with a tolerance of +10% / -15%.

Does it include dynamic braking?

Yes, dynamic braking is included. No external brake chopper is required.

What compliance standards does it meet?

It is listed to UL508C, CSA C22.2 No.14, and EN50178-1997.