96 x 96mm panel cutout, 50 ms loop update
The PXF9APR2-0VMA1: Its 50 ms sampling speed makes it suitable for fast-responding thermal processes where a standard 1-second controller would let overshoot run.
What the 50 ms sampling means on the line
A 50 ms sampling period means the controller reads the input, runs the PID algorithm, and updates the output every 20 cycles on a 50 Hz mains or 16.7 cycles on 60 Hz. For plastic injection barrel zones or reflow oven stages, that update rate catches thermal transients before they propagate to the next zone. The self-tuning function auto-calculates PID constants during the first heat-up cycle, so a commissioning engineer can skip manual loop tuning for most resistive loads.
It is sourced through authorized distribution channels and quoted to order against your BOM quantity. For volume purchases or blanket orders, the pricing and lead time are confirmed at RFQ. No minimum order quantity restrictions apply for standard quantities.