Skip to main content
Fuji Electric VFC100A-7W — Industrial Fans & Blowers

FUJI ELECTRIC VFC100A-7W Ring Compressor, 0.16 hp, 200-230/4

MPNVFC100A-7W

FUJI ELECTRIC Ring Compressor, VFC100A-7W, 0.16 hp, 27 cfm, 25 in wc vacuum, 200-230/460V AC three-phase, 60 Hz, Class B NEMA insulation, TEFC aluminum housing.

$585.54Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

VFC100A-7W — Identification
ParameterValue
Product typeRing Compressor
VFC100A-7W — Air Performance
ParameterValue
Max. flow rate27 cfm
Max. operating pressure26.4 in wc
Max. vacuum25 in wc
VFC100A-7W — Electrical
ParameterValue
Output power0.16 hp
Voltage200-230/460V AC
PhaseThree
Frequency60 Hz
Current rating0.53-0.52/0.27-0.26 A
Thermal protectionPilot Duty
StandardsClass B NEMA Insulation
VFC100A-7W — Mechanical
ParameterValue
Enclosure typeTotally Enclosed Fan-Cooled
Inlet size1 in
Outlet size1 in
Inlet typeNPT
Outlet typeNPT
Inlet connection genderFemale
Outlet connection genderFemale
Housing materialAluminum
Overall length8.34 in
Overall height8.5 in
Overall depth7.87 in
Weight19 lb
VFC100A-7W — Environmental
ParameterValue
Ambient temperature, max.104 °F
Max. air temperature rise72 °F

Product details

The FUJI ELECTRIC VFC100A-7W is a regenerative blower — listed as a Ring Compressor — rated 0.16 hp output, delivering up to 27 cfm at a maximum vacuum of 25 in wc and a maximum operating pressure of 26.4 in wc. That 0.16 hp figure tells you this is a low-power unit sized for light-duty air movement or vacuum pickup, not for bulk conveying or high-pressure aeration. The 27 cfm at 25 in wc vacuum means it can hold a modest suction on a pick-and-place nozzle or a small filtration circuit. Three-phase input at 200-230/460V AC, 60 Hz. Current draw is 0.53-0.52 A on low voltage and 0.27-0.26 A on high voltage.

Construction and environment

Inlet and outlet are both 1-inch NPT female ports. Maximum ambient temperature is 104 °F with a maximum air temperature rise of 72 °F. Thermal protection is listed as Pilot Duty — meaning the internal thermal switch is rated to break a control circuit, not the motor's full-load current directly. In practice, you wire that switch into the contactor coil circuit so an over-temp condition drops the motor starter. Class B NEMA insulation is the standard 130 °C rise class; fine for continuous duty at the rated ambient.

Frequently asked questions

What are the key ratings for the VFC100A-7W?

0.16 hp output, 27 cfm maximum flow, 25 in wc maximum vacuum, 26.4 in wc maximum pressure. Three-phase 200-230/460V AC, 60 Hz, drawing 0.53-0.52 A (low voltage) or 0.27-0.26 A (high voltage). TEFC aluminum housing, 1-inch NPT ports, Class B insulation.

MPN
VFC100A-7W