Specifications

VFC100P-5T — Identification
ParameterValue
Product typeRing Compressor
VFC100P-5T — Air Performance
ParameterValue
Max. flow rate27 cfm
Max. operating pressure27.4 in wc
Max. vacuum26 in wc
VFC100P-5T — Electrical
ParameterValue
Output power0.16 hp
Voltage115/230V AC
PhaseSingle
Frequency60 Hz
Current rating1.5/0.75 A
Thermal protectionAutomatic Reset
StandardsClass B NEMA Insulation
VFC100P-5T — Mechanical
ParameterValue
Enclosure typeTotally Enclosed Fan-Cooled
Inlet size1 in
Outlet size1 in
Inlet typeNPT
Outlet typeNPT
Inlet connection genderFemale
Outlet connection genderFemale
Housing materialAluminum
Overall length8.34 in
Overall height8.5 in
Overall depth7.87 in
Weight19 lb
VFC100P-5T — Environmental
ParameterValue
Ambient temperature, max.104 °F
Max. air temperature rise72 °F

Product details

The FUJI ELECTRIC VFC100P-5T is a regenerative blower — a ring compressor — rated at 0.16 hp on single-phase 115/230V AC, 60 Hz. It delivers up to 27 cfm of air at a maximum vacuum of 26 in wc and a maximum operating pressure of 27.4 in wc. The 1.5/0.75 A current draw reflects the dual-voltage tap; wire it for 115V or 230V depending on your line supply. Class B NEMA insulation on the motor winding means it handles a 104 °F ambient without derating, and the automatic-reset thermal protector cycles the motor off before the winding temperature exceeds the rise limit of 72 °F above ambient. That is standard for continuous-duty blowers in clean-air transfer — if the inlet blocks or the discharge deadheads, the protector resets once the motor cools. Ports are 1 in NPT female on both inlet and outlet, which mates directly to standard schedule-40 pipe or hose adaptors.