Skip to main content
Omron E5EC-TQX4D5M-008

Omron E5EC-TQX4D5M-008 Temperature Controller, 4 Relay + SSR

MPN E5EC-TQX4D5M-008
Active

Omron E5EC-T series, Process / Temperature Controller, universal RTD/TC/analog input, 4 relay + voltage (external SSR) outputs, RS-485 CompoWay/F Modbus, 24VAC/DC, IP66 front panel.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

E5EC-TQX4D5M-008 specifications
ParameterValue
SeriesE5EC-T
Output signalRelay (4), Voltage (External SSR)
Supply voltage24 VAC/DC
IP ratingIP66
ProtocolRS-485 (CompoWay/F, Modbus)
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.463 lb (210.01 g)
PackageBulk
Control methodOn/Off, Proportional (PID)

Product details

Panel-mount controller with universal input and heater fault detection

The Omron E5EC-TQX4D5M-008 is a 1/4 DIN panel-mount process and temperature controller from the E5EC-T series. It accepts a wide range of sensors — RTD, thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, plus 0–20 mA and 0–10 VDC analog signals — making it a single SKU for mixed-sensor lines. The output stage is four relay contacts plus a voltage pulse for driving an external SSR. This split is useful when you need relay outputs for alarm or on/off stages and the SSR drive for a PID-controlled power loop — the SSR output switches faster and avoids relay contact wear on the modulating element. Heater fault detection is built in, not an add-on module. It monitors current draw on the load side and flags a broken heater element or open circuit — a common failure mode in electric furnaces, hot-runner systems, and packaging seal bars.

RS-485 Modbus and event input for supervisory control

RS-485 communications supports both Omron CompoWay/F and standard Modbus protocols. This lets the controller integrate into a PLC-based line control or a SCADA system without a protocol converter — the Modbus mapping is documented in the product manual. An event input is provided for external trigger — typically used to switch between pre-set temperature profiles, hold the PID loop during a recipe change, or reset the heater fault latch from a remote pushbutton. The tri-color LCD display shows three rows of four characters each. The large top row (18 mm) is the process value; the middle and bottom rows can show setpoint, output power, or heater current. Color changes (green, orange, red) per row give at-a-glance status without reading digits.

IP66 front panel and active lifecycle

The front panel is rated IP66, meaning it withstands hose-down and dust ingress when properly gasketed in the panel cutout. This is the standard for food, beverage, and washdown zones — the controller can be mounted directly on the machine face without a secondary enclosure. Supply voltage is 24 VAC/DC, which is common for industrial control panels. The wide tolerance means it works on either an AC control transformer or a DC power supply without rewiring.

MPN
E5EC-TQX4D5M-008