Omron G3PW-A260EC-S-FLK Power Controller, 1-60A, RS-485

MPN G3PW-A260EC-S-FLK
Active

Omron G3PW Series, Power Controller, Solid State (2) Output, 1 ~ 60A Input Range, 100 ~ 240VAC Supply, RS-485 CompoWay/F, Chassis Mount, LED Display.

$811.81 – $890.42 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

G3PW-A260EC-S-FLK specifications
ParameterValue
SeriesG3PW
Output signalSolid State (2)
Display typeLED - Red Characters
Product typePower Controller
Supply voltage100 to 240VAC
ProtocolRS-485 (CompoWay/F)
MountingChassis Mount
Temp operating max55 °C
Temp operating min-15 °C
Weight4.1 lbs (1.9 kg)
PackageBox
Control methodOn/Off, Phase Control

Product details

The Omron G3PW-A260EC-S-FLK is a chassis-mount power controller built for resistive heater loads, with a 1 ~ 60A input current range and dual solid-state outputs. It runs on a 100 ~ 240VAC supply and controls power through on/off or phase-control methods — phase control gives you smooth voltage ramping for heater banks that need soft starts or tight temperature regulation. The LED display shows three characters, enough for local readout of setpoint or load current.

The 1 ~ 60A input range covers small to mid-size heater circuits — think single-zone ovens, extruder barrel heaters, or packaging seal bars. The dual SSR outputs let you drive two independent heater zones from one controller, saving panel space versus running two separate units. Phase control is the key here: it chops the AC waveform to vary power, which is harder on the SSR than simple on/off cycling but gives much finer temperature control and eliminates thermal overshoot on fast-responding loads. Heater fault detection is built in — it monitors current draw and flags a broken heater element or open circuit. That's a real time-saver on the route: instead of waiting for a temperature drop to tell you a heater died, the controller catches it at the next cycle and fires the event input. The RS-485 CompoWay/F communication lets a PLC or HMI poll the controller for status and setpoint changes over a daisy-chained network, which keeps wiring simple on multi-zone machines.