Omron G3PW-A260EC-S-FLK Power Controller, 1-60A, RS-485

MPNG3PW-A260EC-S-FLK
Active

Omron G3PW Series, Power Controller, Solid State (2) Output, 1 ~ 60A Input Range, 100 ~ 240VAC Supply, RS-485 CompoWay/F, Chassis Mount, LED Display.

$811.81 – $890.42Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

G3PW-A260EC-S-FLK — Specifications
ParameterValue
TypePower Controller
SeriesG3PW
Weight4.1 lbs (1.9 kg)
FeaturesEvent Input, Heater Fault Detection
Input range1 ~ 60A
Output signalSolid State (2)
Display typeLED - Red Characters
MountingChassis Mount
CommunicationsRS-485 (CompoWay/F)
Control methodOn/Off, Phase Control
Supply voltage100 ~ 240VAC
Termination styleScrew Terminal
Operating temperature-15°C ~ 55°C
Number of characters per row3

Product details

The Omron G3PW-A260EC-S-FLK is a chassis-mount power controller built for resistive heater loads, with a 1 ~ 60A input current range and dual solid-state outputs. It runs on a 100 ~ 240VAC supply and controls power through on/off or phase-control methods — phase control gives you smooth voltage ramping for heater banks that need soft starts or tight temperature regulation. The LED display shows three characters, enough for local readout of setpoint or load current.

The 1 ~ 60A input range covers small to mid-size heater circuits — think single-zone ovens, extruder barrel heaters, or packaging seal bars. The dual SSR outputs let you drive two independent heater zones from one controller, saving panel space versus running two separate units. Phase control is the key here: it chops the AC waveform to vary power, which is harder on the SSR than simple on/off cycling but gives much finer temperature control and eliminates thermal overshoot on fast-responding loads. Heater fault detection is built in — it monitors current draw and flags a broken heater element or open circuit. That's a real time-saver on the route: instead of waiting for a temperature drop to tell you a heater died, the controller catches it at the next cycle and fires the event input. The RS-485 CompoWay/F communication lets a PLC or HMI poll the controller for status and setpoint changes over a daisy-chained network, which keeps wiring simple on multi-zone machines.

Frequently asked questions

What is the G3PW-A260EC-S-FLK used for?

It's a power controller for resistive heater loads, using solid-state outputs to switch 1 ~ 60A at 100 ~ 240VAC. Typical applications include industrial ovens, packaging seal bars, extruder heaters, and any multi-zone electric heat system needing phase control or heater fault detection.

Where can I buy the G3PW-A260EC-S-FLK?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Does the G3PW-A260EC-S-FLK have heater fault detection?

Yes, it includes heater fault detection as a built-in feature. It monitors the load current and flags an open or failed heater element, which can be read via the event input or communicated over RS-485.

MPN